Steps
1. Reboot the BMC if the replacement module is not the same model as the old module:
a.
From the LOADER prompt, change to advanced privilege mode:
priv set advanced
b.
Reboot the BMC:
sp reboot
2.
From the LOADER prompt, reboot the node:
bye
This reinitializes the PCIe cards and other components and reboots the node.
3. If your system is configured to support 10 GbE cluster interconnect and data connections on 40 GbE NICs,
convert these ports to 10 GbE connections by using the nicadmin convert command from Maintenance
mode. See
Convert 40GbE NIC ports into multiple 10GbE ports for 10GbE connectivity for more
information.
Be sure to exit Maintenance mode after completing the conversion.
4.
Return the node to normal operation:
storage failover giveback -ofnode
impaired_node_name
5.
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto
-giveback true
Step 4: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Replace an LED USB module - AFF A900
The LED USB module provides connectivity to console ports and system status.
Replacement of this module does not require tools and does not interrupt service.
Step 1: Replace the LED USB module
Steps
1. Remove the old LED USB module:
Animation - Remove/install LED-USB module