EasyManua.ls Logo

NetApp AFF - Page 1094

NetApp AFF
1152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration State is configured and that the nodes are in an enabled and normal state
(
metrocluster node show).
Steps
1. If AutoSupport is enabled, suppress automatic case creation by invoking an AutoSupport message:
system node autosupport invoke -node * -type all -message
MAINT=number_of_hours_downh
The following AutoSupport message suppresses automatic case creation for two hours:
cluster1:*> system node autosupport invoke -node * -type all -message
MAINT=2h
2.
Disable automatic giveback from the console of the healthy controller:
storage failover modify
–node local -auto-giveback false
3. Take the impaired controller to the LOADER prompt:
If the impaired controller is
displaying…
Then…
The LOADER prompt Go to Remove controller module.
Waiting for giveback…
Press Ctrl-C, and then respond y when prompted.
System prompt or password
prompt (enter system password)
Take over or halt the impaired controller from the healthy
controller:
storage failover takeover -ofnode
impaired_node_name
When the impaired controller shows Waiting for giveback…, press
Ctrl-C, and then respond
y.
Replace the controller module hardware - AFF A900
To replace the controller module hardware, you must remove the impaired controller,
move FRU components to the replacement controller module, install the replacement
controller module in the chassis, and then boot the system to Maintenance mode.
The following animation shows the whole process of moving components from the impaired to the replacement
controller.
AnimationMove components to replacement controller
Step 1: Remove the controller module
To access components inside the controller, you must first remove the controller module
from the system and then remove the cover on the controller module.
1. If you are not already grounded, properly ground yourself.
2. Unplug the cables from the impaired controller module, and keep track of where the cables were
connected.