b. If you have not already done so, reinstall the cable management device.
c. Bind the cables to the cable management device with the hook and loop strap.
d. Repeat the preceding steps for the second controller module in the new chassis.
5. Connect the power supplies to different power sources, and then turn them on.
6. Boot each controller to Maintenance mode:
a.
As each controller starts the booting, press
Ctrl-C to interrupt the boot process when you see the
message
Press Ctrl-C for Boot Menu.
If you miss the prompt and the controller modules boot to ONTAP, enter halt, and then
at the LOADER prompt enter
boot_ontap, press Ctrl-C when prompted, and then
repeat this step.
b. From the boot menu, select the option for Maintenance mode.
Restore and verify the configuration - AFF C190
You must verify the HA state of the chassis and run System-Level diagnostics.
Step 1: Verify and setting the HA state of the chassis
You must verify the HA state of the chassis, and, if necessary, update the state to match your system
configuration.
1. In Maintenance mode, from either controller module, display the HA state of the local controller module and
chassis:
ha-config show
The HA state should be the same for all components.
2. If the displayed system state for the chassis does not match your system configuration:
a. Set the HA state for the chassis:
ha-config modify chassis HA-state
The value for HA-state can be one of the following:
ha
non-ha
b. Confirm that the setting has changed:
ha-config show
3. If you have not already done so, recable the rest of your system.
4. The next step depends on your system configuration.