If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a.
Clear the status logs:
sldiag device clearstatus
b.
Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c.
Exit Maintenance mode:
halt
The controller displays the LOADER prompt.
d.
Boot the controller from the LOADER prompt:
bye
e. Return the controller to normal operation:
If your controller is in… Then…
An HA pair
Perform a give back: storage failover giveback -ofnode
replacement_node_name
If you disabled automatic giveback, re-enable it with
the storage failover modify command.
A two-node MetroCluster
configuration
Proceed to the next step. The MetroCluster switchback procedure is
done in the next task in the replacement process.
A stand-alone configuration Proceed to the next step. No action is required.
You have completed system-level diagnostics.
463