EasyManua.ls Logo

NetApp AFF - Page 556

NetApp AFF
1152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The latching mechanism arms slide into the chassis.
The controller module begins to boot as soon as it is fully seated in the chassis.
e. Release the latches to lock the controller module into place.
f. Recable the power supply.
g. If you have not already done so, reinstall the cable management device.
h.
Interrupt the normal boot process by pressing
Ctrl-C.
Step 5: Run diagnostics
After you have replaced the NVDIMM in your system, you should run diagnostic tests on
that component.
Your system must be at the LOADER prompt to start diagnostics.
All commands in the diagnostic procedures are issued from the controller where the component is being
replaced.
1.
If the controller to be serviced is not at the LOADER prompt, reboot the controller:
system node halt
-node node_name
After you issue the command, you should wait until the system stops at the LOADER prompt.
2. At the LOADER prompt, access the special drivers specifically designed for system-level diagnostics to
function properly:
boot_diags
3. Select Scan System from the displayed menu to enable running the diagnostics tests.
4. Select Test Memory from the displayed menu.
5. Select NVDIMM Test from the displayed menu.
6. Proceed based on the result of the preceding step:
If the test failed, correct the failure, and then rerun the test.
If the test reported no failures, select Reboot from the menu to reboot the system.
Step 6: Restore the controller module to operation after running diagnostics
After completing diagnostics, you must recable the system, give back the controller
module, and then reenable automatic giveback.
1. Recable the system, as needed.
If you removed the media converters (QSFPs or SFPs), remember to reinstall them if you are using fiber
optic cables.
2.
Return the controller to normal operation by giving back its storage:
storage failover giveback
-ofnode impaired_node_name
3.
If automatic giveback was disabled, reenable it: storage failover modify -node local -auto
-giveback true
554

Related product manuals