8) Press [] to save any changes. The panel is now wait-
ing for the next location entry.
Note: Pressing [#] does not save changes to the cur-
rent segment, but does save changes made in
previous segments.
9) Enter [EXIT] [EXIT] when all changes are completed.
Programming Transmitter and Partition
Settings
1) Enter [] [8] at the keypad. The five function lights
should start flashing.
2) Enter the “Go To Program Code” (factory default is 9 7
1 3). The service light should flash and the five func-
tion lights should change from flashing to on steady.
3) Enter [XX] [#], where [XX] is the DIP switch setting
module number and [#] is the entry key. The Armed
LED should turn on, indicating the control panel is
waiting for a programming location entry.
4) Enter [XX] [#] to enter a location. For example, enter
[1] [#] to enter location 1, segment 1. The Armed LED
should turn on and the zone LEDs display the binary
data for the current settings.
or-- Enter [1] [#] [] to enter location 1, segment 2.
5) Enter [X] [], where [X] is the setting number (1 - 8)
from Table 5 that corresponds to the desired feature or
partition setting number and [] is the entry key. The
keypad displays the settings for that location and seg-
ment.
6) Press the keypad button that corresponds to the feature
number you want changed. Lights corresponding to the
feature number turn on or off each time the button is
pressed. Lights that turn on indicate the feature is on,
lights that turn off indicate the feature is off.
For example, turn on transmitter features 1 (Transmit-
ter Enabled) and 3 (Input Option 1) by pressing [1] [3].
The 1 and 3 LEDs turn on to indicate the features are
turned on and the Ready LED flashes to indicate the
change request.
7) Press [] to enter the changes and automatically
advance to segment 2.
Note: Pressing [#] does not save changes to the cur-
rent segment, but does save changes made in
previous segments. Repeat steps 4 - 7 to re-
enter and make changes to a location and seg-
ment.
8) Press the keypad button that corresponds to the parti-
tion number you want changed. Lights corresponding
to the partition number turn on or off each time the but-
ton is pressed. Lights that turn on indicate the keyfob is
active in that partition, lights that turn off indicate the
keyfob is inactive.
9) Repeat steps 4 - 8 to continue programming transmitter
partition settings.
10) Enter [EXIT] [EXIT] when finished.
Deleting Transmitters
The following steps describe how to delete transmitters from
the module.
This procedure makes the module ignore a transmitter but
does not remove transmitter identification from the mod-
ule’s memory. The transmitter can be reactivated later or a
new one can be learned into the zone.
1) Enter [] [8] at the keypad. The five function lights
should start flashing.
2) Enter the “Go To Program Code” (factory default is 9 7
1 3). The service light should flash and the five func-
tion lights should change from flashing to on steady.
3) Enter [XX] [#], where [XX] is the DIP switch setting
module number and [#] is the entry key. The Armed
LED should turn on, indicating the control panel is
waiting for a programming location entry.
4) Enter [XX] [#] to enter the zone location to be deleted.
The Armed LED should turn on and the zone LEDs
display the binary data for the current settings.
5) Change transmitter feature 1 (Transmitter Enabled) by
pressing [1]. The 1 LED turns off to indicate the feature
change and the Ready LED flashes to indicate the
change request.
6) Enter [] [#]. The Ready LED stops flashing, indicat-
ing the new settings are stored in memory and the sys-
tem automatically exits from that location.
7) Continue deleting transmitters by entering the desired
locations and segments in steps 4 through 6.
or-- Enter [9] [1] [0] [#] to delete all transmitters and load
factory defaults.
8) Enter [EXIT] [EXIT] when finished.
Testing Wireless Transmitters
Test all transmitters to verify correct programming and
operation, using the steps below.
1) Trip a transmitter (open a door, walk in front of a PIR,
etc.).
2) Enter [] [8] at the keypad. The five function lights
should start flashing.
3) Enter the “Go To Program Code” (factory default is 9 7
1 3). The service light should flash and the five func-
tion lights should change from flashing to on steady.
4) Enter [XX] [#], where [XX] is the DIP switch setting
module number and [#] is the entry key. The Armed
LED should turn on, indicating the control panel is
waiting for a programming location entry.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetworX NX Series and is the answer not in the manual?

NetworX NX Series Specifications

General IconGeneral
Input Voltage16.5 VAC
PartitionsUp to 8
Power Supply16.5VAC
Backup Battery12VDC, 7AH
Event Buffer1000 events
Wireless ZonesUp to 128
Operating Temperature0°C to 49°C (32°F to 120°F)