Maintenance
YoushouldinspecttheairfilterintheAirCompressorAssemblytoseeifit
isexcessivelydirty.Ifitisdirty,followthestepsbelow
toreplaceit.
1.Unplugthespraygun.Remove
thefiltercoverwithatool
(suchasaflatscrewdriver)
2.Removethedirty
filtersandreplace
withnewones.
3.Securethecoverbackontotheturbine.
Neveroperateyourunitwithouttheairfilters.Dirtcould
besuckedinandinterferewiththefunctionoftheunit.
Troubleshooting
Problem
A.Littleornomaterialflow
B.Materialleaking
C.Atomizationistoocoarse
D.Sprayjetpulsates
E.Patternrunsorsags
F.Toomuchoverspray
G.Patternisverylightand
splotchy.
Cause
1.Nozzleclogged.
2.Suctiontubeclogged.
3.Materialvolumesettingturnedtoolow().
4.Suctiontubeloose.
5.Nopressurebuildupincontainer.
6.Airfilterclogged.
1.Nozzleloose.
2.Nozzleworn.
3.Nozzlesealworn.
4.Materialbuilduponaircapandnozzle
1.Viscosity
ofmaterialtoohigh.
2.Materialvolumetoolarge.
3.Materialvolumesettingtoohigh(+).
4.Nozzleclogged.
5.Airfilterclogged.
6.Toolittlepressurebuildupincontainer.
1.Materialincontainerrunningout.
2.Airfilterclogged.
1.Applyingtoomuchmaterial.
1.Guntoofar
fromsprayobject.
2.Toomuchmaterialapplied.
1.Movingthesprayguntoofast
Solution
1.Clean.
2.Clean.
3.Increasevolumesetting(+).
4.Insert.
5.Tightencontainer.
6.Change.
1.Tighten.
2.Replace.
3.Replace.
4.Clean.
1.Thin.
2.Decreasevolumesetting().
3.Decreasevolumesetting().
4.Clean.
5.Change.
6.Tightencontainer.
1.Refill.
2.Change.
1.Adjust
materialfloworincrease
movementofspraygun.
1.Reducedistance.
2.Decreasevolumesetting().
1.Adjustmaterialflowordecrease
movementofspraygun.
7