EasyManua.ls Logo

New Cosmos Electric ML-310 - Troubleshooting; Specifications; Contact Details; Disposal

New Cosmos Electric ML-310
5 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
household vacuum's soft brush attachment.
Never use water, cleaners or solvents since they may
damage the unit.
Do not use spray cleaning chemicals or insect sprays
directly on or near the device. Do not use any
household cleaning agents, ammonia-based
cleaners, paints, varnishes, aerosol sprays (including
compressed gas dusters), or any other chemical on or
near this device.
Troubleshooting
Symptom
Cause
Action
The green LED
does not flash
even when the
switch is
pressed
Battery connector not
plugged in
Plug in the battery
connector
Battery is low
Contact
manufacturer for
replacement
The yellow LED
is flashing.
Flashes three times
every 10 seconds:
Gas alarm trouble
Replace gas
alarm
Flashes twice every 10
seconds:
End of gas alarm
service life
Replace gas
alarm
Flashes once every 10
seconds:
Low gas alarm battery
Contact
manufacturer for
replacement
Disposal
DANGER
Prior to disposing of product, remove and wrap
the removed battery with tape or similar material
to avoid potential explosion or ignition that may
result in injury or fire.
DANGER
Do not incinerate. Battery may explode.
When disposing of product, remove the battery and wrap
with tape or similar, non-flammable material.
Dispose of battery in accordance with local regulations
relating to non-rechargeable (single use) lithium batteries.
Dispose of remainder of device following your local
regulations for solid waste disposal. Take the device to an
electronics recycling facility (where such facilities exist) for
disposal.
Specifications
Model number
ML-310
Conforming standards
UL standard (UL1484)
Detection principle
MEMS hot wire semiconductor sensor
Target gas
Methane gas (Natural Gas)
Operating temperature
range
32°F (0°C) to 122°F (50°C)
Operating humidity
range
5% to 95%, no condensation
Power supply
3V Lithium battery
Alarm level
10% LEL*
Speaker output
Gas alarm: 85 dB at 10 feet
Battery lifetime
Approximately 6 years
Dimensions
W 85 × H 110 × D 22 mm
Installation
Pipe mount by cable ties or wall mount
with hardware.
*LEL, short for “Lower Explosive Limit”, is defined as the lowest
concentration (by percentage) of a gas or vapor in air that is capable of
producing a flash of fire in presence of an ignition source (arc, flame,
heat).
Contact Details
New Cosmos USA, Inc.
650 Warrenville Rd, Suite 101
Lisle, IL, 60532
Phone: (847) 749 3064

Related product manuals