SECTION 3 -- FIELD OPERATION
3--8
GRID HEATER COLD START AID
(where fi tted)
WARNING
If your tractor is equipped with a Grid Heater
electronic cold weather starting device, do not use
ether as a starting aid. It will explode in the intake
manifold. If any difficulty is experienced when trying
to start your tractor in cold temperatures, consult
your authorised dealer .
The grid heater, which is effective in ambient
temperatures down to --18° C(0° F), consists of a
heating element installed in the intake manifold.
Operation of the grid heater is automatic when the
the engine coolant temperature falls to 0° (32° F)or
below.
A warning light on the instrument panel will illuminate
to confirm operation.
Key Start Switch (with Grid Heater)
A five-position key-start switch is installed. The
key-start switch positions are as follows:
Position 1 Not used
Position 2 Off
Position 3 Accessories on
Position 4 W arning lights, instruments and
Grid Heater on
Position 5 Grid heater on, starter motor
engaged
IMPORTANT: Never push or tow the tractor to start
the engine. Use an auxiliary battery and jump leads.
NOTE: Neutral start switches prevent operation of
the starting motor unless the shuttle lever is in the
neutral (N) position.
6