NEXT UPS Systems MINT+
700-1500 VA UPS Quick Guide
Languages: EN, DE, FR
Question and Answer IconNeed help?

Do you have a question about the Next MINT+ Series and is the answer not in the manual?

Next MINT+ Series Specifications

General IconGeneral
BrandNext
ModelMINT+ Series
CategoryPortable Generator
LanguageEnglish

Summary

Overview of NEXT UPS Systems MINT+

LCD Display

Shows UPS status including input voltage, output voltage, load, and battery level.

Control Buttons

Includes Up/down, Mute, and ON/OFF buttons for operating the UPS.

USB Ports and Connectivity

Features a USB charging port and a HID-compliant communication port.

Outlets and Protection

Includes surge-protected outlets and battery backup outlets.

AC Input and Ventilation

Covers AC power input connection and cooling vents.

Circuit Breaker

Protects the UPS from overcurrents and short circuits.

UPS Operation and Controls

Powering On;Off

Press and hold ON/OFF button for 2 seconds to change state between Standby and Line.

Alarm Muting

Press and hold Mute button for 1 second to mute or unmute audible alarms.

Display Navigation

Click the Up/down button to cycle through displayed information.

Understanding the UPS Display

General Display Information

Shows input/output voltage, frequency, battery voltage, power, backup time, and load.

UPS Operating Modes

Indicates Line Mode, AVR Mode, Battery Mode, and Mute status.

Battery and Load Status

Displays battery level, low battery warnings, and load percentage.

Alerts and Faults

Shows overload indicators, battery replacement needs, fault codes, and high battery voltage.

Battery Replacement Procedure

Preparation Steps

Turn off equipment and UPS, unplug input cable, and remove battery cover screws.

Battery Disconnection and Removal

Disconnect battery connector and slide out the old battery pack carefully.

Installing New Battery

Slide in the new battery pack, verify polarity, and reconnect connectors.

Final Steps and Disposal

Reinstall cover, ensure normal operation, and dispose of old batteries properly.

Troubleshooting Common Issues

Fault Code E04

Battery mode output high (internal fault).

Fault Code E01

Output short (check the loads).

Fault Codes E05;E06

Over Charge Voltage or Low battery voltage.

Fault Code E02

Overload fault.

Technical Specifications

General Specifications

Input voltage, range, output voltage regulation, transfer time, and waveform.

Performance Metrics

Details charging time and operating humidity.

Model Specifics

Lists POWER, Batteries, Dimension, and Net Weight for MINT+ series models.