Module EP14 prioritises hot water charging via a reversing
valve. When the hot water heater/accumulator tank is fully
charged, the reversing valve switches to the heating circuit.
The heat pump is controlled by an outdoor sensor combined
with the flow line sensor which must be placed on the main
pipe to the radiators. ELK 15 is connected automatically when
the energy requirement exceeds the heat pump capacity.
Menu settings
1.
Set start diff additional heat and diff. between additional
steps in menu 4.9.3 - degree minute setting.
2.
Set whether there should be binary control or not, max
step and fuse size in menu 5.1.12 - step controlled add.
heat.
See the “Installer manual” for F1345 for more information.
ELK 1510
For the Installer
Installation alternative