GENERAL
ROT 10 is a wireless room thermostat and humidity
sensor, which can monitor and control the temperature
in a room or zone, both from the app on your smart-
phone and using the room thermostat. It helps you to
achieve a comfortable indoor temperature and gives you
the opportunity to save energy by having different tem-
peratures in different parts of your house.
AREAS OF APPLICATION
Temperature control
ROT 10 can be used to measure, display and set the
temperature in the zone in which it is placed.
Control of the humidity level
Heating
Limit relative humidity level (RH) during heating opera-
tion.
If the menu setting "Limit RH" is selected, the system
responds by adjusting the temperature to raise or
lower the humidity.
Cooling
Limit relative humidity level (RH) during cooling opera-
tion.
If the menu setting "Limit RH in cold" is selected, the
system responds by adjusting the temperature to raise
or lower the humidity.
Limit cooling supply to prevent condensation on pipes
and components in the cooling system.
If the menu setting "Prevent condensation in cold" is
selected, the system responds by adjusting the tem-
perature of the cooling supply to prevent condensa-
tion.
Demand-controlled ventilation (DCV)
When activating demand-controlled ventilation, the heat
pump/control module is allowed to affect the ventilation
in order to achieve the desired indoor climate.
If demand-controlled ventilation is activated, you can
select how much the exhaust air fan’s speed will be
affected. The speed of any supply air fan will be adjus-
ted by the same number of percentage points to
maintain the correct ventilation.
If multiple ROT 10 are activated in a zone that is set
to affect the ventilation, the average value from the
sensors will be used to control the ventilation.
Caution
The zone that will be affected by ROT 10 is set
in the main product’s menu 1.3.3.
COMPATIBLE PRODUCTS
S1155
S1255
VVM S320
VVM S325
SMO S40
CONTENTS
ROT 101 x
Wall mounting plate1 x
Self-adhesive assembly tape1 x
Mounting screws2 x
Quick guide1 x