ENGLISH – 21
PROGRAMMING
7
8 PROGRAMMING
The control unit can be programmed by adjusting the trimmers (A-
E) and switches (F)
They are shown here below with their factory settings.
OK RON
Speed- Pause +
PROG RADIO
CL
13
14
15
RX
IBT4N
OP
SbS
Force LowS. LowF.
SWITCH 114
AERIAL
41
l
Refer to chapters "Programming the control unit"
and "Adjusting the trimmers" for the complete list
of parameters and the relative selectable values.
7.1 ADJUSTING THE TRIMMERS
The control unit has ve trimmers (see "Figure 41"), which are de-
scribed in the following table.
m
To make the trimmer adjustment effective, switches
13 and 14 should be set to “OFF” before the adjust-
ment, and set back to “ON” once it is complete.
To assess the effect of the trimmer adjustments, it is advisable to
have the barrier mechanism perform some opening and closing
manoeuvres.
Do this operation manually (hold-to-run):
1. set switches 13 and 14 (A) to “OFF”
2. if you are doing this procedure for the rst time, set all trim-
mers to the halfway point
3. by acting on the devices connected to the Step-by-step,
Open and Close inputs, have the barrier mechanism per-
form some opening and closing manoeuvres: check that
the boom movement begins with a phase of acceleration,
followed by a constant speed, and that it starts the deceler-
ation phase 20° before the mechanical stop
4. release the control button to immediately stop the manoeu-
vre: if the SbS (Step-by-Step) input is used as a control, the
rst movement after the stop will be an opening manoeuvre
5. adjust the trimmers so that the operation of the automated
system is as you require
6. set switches 13 and 14 (A) back to “ON”.
Table 5
ADJUSTING THE TRIMMERS
Trimmer Description
A Pause
Sets the time between the end of an opening manoeuvre and the start of the next closing manoeuvre.
Only valid if the control unit is programmed in Automatic operating mode ("Table 6").
B Speed
Adjusts the maximum speed of the boom from the start of movement to the slowing cam.
It must be set so as not to create jerking movements during normal operation; the movement must be as even as
possible.
C Force
Adjusts the intervention threshold of the obstacle detector from the start of movement to the slowing cam.
If an obstacle is encountered, the manoeuvre is completely reversed. A brief reversal takes place after the third
consecutive intervention.
D Low Speed
Adjusts the speed of the slowing cam up to the end of travel.
It must be set so as not to create jerking movements during normal operation; the movement must be as even as
possible.
E Low Force
Adjusts the intervention threshold of the obstacle detector from the slowing cam up to the end of travel.
In the event of an obstacle where no positions have been acquired or within the "non-reversal zone", the manoeuvre is
immediately stopped.
Where positions have been acquired or outside the "non-reversal zone", the manoeuvre is completely reversed.
A brief reversal takes place after the third consecutive intervention.