TORQMAX F5 Drive v3.xx Parameters Table
42-02-7223 C1 9-27
9
iControl DC
TORQMAX F5 Drive v3.xx Parameters Table
Enter the settings you make while adjusting into the Field column of the following table.
Table 9.6 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para Name Setting Num Range Units Default
Field
Setting
WARNING: Do not change drive parameters while the elevator is running. Incorrect drive
parameter values can cause erratic operation.
WARNING: Parameters with an asterisk (*) must be set correctly for your specific motor /
machine / job. Refer to the adjustment manual for detailed information.
CH Configuration Handling Parameters
CH01
Default
Parameters
Off - No action taken 0
--Off Off
Factory Reset-Will load
defaults, as created by
controller OEM
1
CH02
Save
Parameters
Off - No action taken 0
--Off Off
Save to Flash-All current
parameter settings are saved
to keypad operator flash
memory
1
This function is not available 2
Write to Drive- Current ke
pad operator settings
downloaded to drive
3