Reference
9-28 Manual # 42-02-7223 C1
CH03
Restore
Parameters
Off - No action taken 0 --
Off Off
Restore from Flash-
Previously saved parameter
settings are restored from
internal keypad operator flash
1 --
Load Parameters- Select
below MCE config file as per
controller Type and AC
machine.
ECLIMGLS.DW5 1828-Element closed
loop with Induction Gearless Machine
ECLIMGRD.DW5 1826- Element
closed loop with Induction Geared
Machine
ECLPMGLS.DW5 1833- Element
closed loop with PM Gearless Machine
ECLPMGRD.DW5 1831- Element
closed loop with PM Geared Machine
EOLIMGRD.DW5 1811- Element open
loop with Induction Geared Machine
ICLIMGLS.DW5 1828- iController
closed loop with Induction Gearless
Machine
ICLIMGRD.DW5 1826- iController
closed loop with Induction Geared
Machine
ICLPMGLS.DW5 1832- iController
closed loop with PM Gearless Machine
ICLPMGRD.DW5 1830- iController
closed loop with PM Geared Machine
IOLIMGRD.DW5 1811- iController
open loop with Induction Geared
Machine
MCLIMGLS.DW5 1828- Motion closed
loop with Induction Gearless Machine
MCLIMGRD.DW5 1826- Motion closed
loop with Induction Geared Machine
MCLPMGLS.DW5 1833- Motion closed
loop with PM Gearless Machine
MCLPMGRD.DW5 1831- Motion
closed loop with PM Geared Machine
MOLIMGRD.DW5 1811- Motion open
loop with Induction Geared Machine
2 --
Restore from Drive- Current
drive settings are uploaded
from drive to keypad operator
3 --
Load Motor Data- Loads data
from .dw5 stored to flash.
4 -
CH05 Motor Type --0-76 - --
CH06 Rope Ratio
1:1
2:1
4:1
0
1
2
--1:1 -
CH07 Contract Speed See parameter description - 0-14 ft/min --
CH08 Car Capacity See parameter description - 0-11 lbs --
CH09
Program the
selection
Off
Program
0
1
- -Off Off
Table 9.6 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para Name Setting Num Range Units Default
Field