Reference
9-30 Manual # 42-02-7223 C1
DG10
Modulation
Grade
- - 0-110 % 0 -
DG11 Output Status
None
O1
O2
RLY1
RLY2
0
1
2
4
8
0 - 0 -
DG16
Output
Condition
State
None
Condition 0
Condition 1
Condition 2
Condition 3
Condition 4
Condition 5
Condition 6
Condition 7
0
1
2
4
8
16
32
64
128
0 - 0 -
DG17
Output
Frequency
--
-400.0-
400.0
Hz 0.0 -
DG18 Output Voltage --0-1000 Volts 0 -
DG19 Parameter Set --0-7 - 0 -
DG20 Raw Pattern --
-10.00-
10.00
VDC 0.00 -
DG21
Processed
Pattern
--
-10.00-
10.00
VDC 0.00 -
DG30 Peak DC Volts --0-1500 Volts 0 -
DG31 Peak Current --
-3200.0-
3200.0
Amps 0.0 -
DG32 Peak Speed --0-2500 ft/min 0 -
DG33 Raw Pretorque --
-10.00-
10.00
VDC 0.00 -
DG34 Post Pretorque --
-10.00-
10.00
VDC 0.00 -
DG35
Analog
Output 1
--
-10.00-
10.00
VDC 0.00 -
DG36
Analog
Output 2
--
-10.00-
10.00
VDC 0.00 -
DG37
Heatsink
Temp erat u re
--0-120
Degrees
Celsius
0 -
DG38
Motor
Temp erat u re
--
0: T1-T2
Closed-150
Degrees
Celsius
0 -
DG39
Carrier
Frequency
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
0
1
2
3
4
2kHz0 -
DG40 Electric Power --
-320.0-
320.0
kW 0.0 -
DG41 Motor Power --
-320.0-
320.0
kW 0.0 -
Table 9.6 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para Name Setting Num Range Units Default
Field
Setting