TORQMAX F5 Drive v3.xx Parameters Table
42-02-7223 C1 9-31
9
iControl DC
DG42 Braking Energy --0-65535 kWh 0 -
DG43
Power On
Counter
--0-65535 hr 0 -
DG44
Run Time
Counter
--0-65535 hr 0 -
DG45
Overload
Counter
--0-100 % 0 -
DG46 Drive Load --0-500 % 0 -
DG47 Peak Load --0-500 % 0 -
DG50 Elevator Speed --0-2000 ft/min 0 -
DG51 Mode See Section 6.16 - 0-0 -
DG52 Active Profile
None
Inspection
High Speed
One Floor
Emergency
Correction
Emergency Slowdown
0
1
2
4
8
16
32
0 - 0 -
DG53 Active Speed
None
Inspection Speed
Leveling Speed
Correction Speed
High Speed
Intermediate Speed 1
Earthquake Speed
Intermediate Speed 2
Emergency Generator Speed
Intermediate Speed 3
UPS Speed
0
32
64
96
128
160
256
384
512
640
768
0 - 0 -
DG54
Leveling
Distance
--0.0-18.0 in 0.0 -
DG55 Target Floor --0-64 - 0 -
DG56 Current Floor --0-64 - 0 -
DG57
Next Available
Floor
--0-64
- 0 -
DG58 Car Load ---100- 100 % 0 -
DG59
Brake Release
Time
--0.00-5.00 sec 0.00 -
DG60
Average Regen
Power
--0.0- 3000.0 kW 0.0 -
DG61
Peak Regen
Power
--0.0- 3000.0 kW 0.0 -
DG62 Runs Per Hour --0-500 - 0 -
DG63
NTSD Speed 1
Up
-
--ft/min --
DG64
NTSD Speed 2
Up
---ft/min --
Table 9.6 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para Name Setting Num Range Units Default
Field
Setting