Unidrive M400 Step By Step Guide 9
Issue Number: 2
English
Français Deutsch Italiano Español
Table 11-1 Status indications
STEP 12: Understand key parameters and restoring default
When changing a parameter, the new value is saved when pressing the Enter button to return to parameter view
mode from parameter edit mode.
Restoring default parameters:
1. Ensure the drive is not enabled, i.e. terminal 31 and 34 are open.
2. Select ‘Reset 50 Hz Defs’ (50 Hz settings) or ‘Reset 60 Hz Defs’ (60 Hz settings) in Pr 00.000
3. Press the red reset button
String Description
Drive output
stage
Inhibit
The drive is inhibited and cannot be run. The Drive Enable signal is not applied to
the drive enable terminal or is set to 0.
Disabled
Ready
The drive is ready to run. The drive enable is active, but the drive inverter is not
active because the final drive run is not active
Disabled
Stop The drive is stopped / holding zero speed. Enabled
Supply Loss Supply loss condition has been detected Enabled
dc Injection The drive is applying dc injection braking Enabled
Trip
The drive has tripped and no longer controlling the motor. The trip code appears on
the display.
Disabled
Under
Voltage
The drive is in the under voltage state. Disabled
Parameter Range (Ú) Default (Ö)
00.001 Minimum Speed 0.00 to Pr 00.002 Hz 0.00 Hz
00.002 Maximum Speed 0.00 to 550.00 Hz
Def.50: 50.00 Hz
Def.60: 60.00 Hz
00.003 Acceleration Rate 1 0.0 to 32000.0 s/100 Hz 5.0 s/100 Hz
00.004 Deceleration Rate 1 0.0 to 32000.0 s/100 Hz 10.0 s/100 Hz
00.005 Drive Configuration
Refer to the Quick Start Guide for further
information on all drive configurations
AV
00.006 Motor Rated Current 0.00 to Drive Rating Amps
Maximum Heavy Duty
Rating Amps
00.007 Motor Rated Speed 0.0 to 33000.0 rpm
Def.50: 1500.0 rpm
Def.60: 1800.0 rpm
00.008 Motor Rated Voltage 0 to 240 V or 0 to 480 V
110V drive: 230 V
200V drive: 230 V
400V drive Def.50: 400 V
400V drive Def.60: 460 V
00.009 Motor Rated Power Factor 0.00 to 1.00 0.85
00.010 User Security Status
Refer to the Quick Start Guide for further
information
Level 1