Do you have a question about the nifty HR12 and is the answer not in the manual?
Confirm all labels, placards, and the operating safety manual are present and legible.
Check chassis, booms, platform, welds, guards, and wheels for damage or missing components.
Inspect platform load sensor, tilt sensor, alarm horn, and various switches for functionality.
Verify all operating, emergency, and manual descent controls function correctly.
Check hydraulic, fuel, air systems, and electrical cables for damage or leaks.
Examine batteries, engine oil, and coolant for condition and correct fluid levels.
Ensure safety harnesses, lanyards, and hard hats are in good condition and fit for purpose.
Inspect the area around the platform for obstructions or hazards before operation.
Ensure emergency stops are out and set key switch and selector valve correctly.
Push the green power button and select the desired boom function.
Stow the machine, turn off the key switch, remove the key, and chock wheels.
Check proposed route for possible hazards, obstructions, and personnel.
Use the drive speed selector for High or Low gradeability.
Operate the drive joystick for forward, reverse, and steering functions.
Understand slope limits and tilt alarm activation during operation.
Use ground controls to manoeuvre the machine if the operator is incapacitated.
Use the Manual Hand Pump for hydraulic power to manoeuvre the machine.
Recover machine using Manual Hand Pump if cage contacts an object.
Extend and retract all cylinders from ground control after emergency descent.
Ensure operators read and understand the relevant operating and safety manual.
Perform visual and functional tests before each day and shift.
Repair any malfunctions affecting operational safety before further use.
Check the work area for hazards like uneven ground, obstructions, and weather.
Maintain a minimum 4.0m clearance from electrical power lines.
Remain standing within the platform; do not climb on guardrails or use aids.
Do not lift overhanging items or objects that increase wind loading.
Elevate booms 250mm before slewing and check clearance during lowering.
Stunt driving, horseplay, and using the Niftylift as a crane are prohibited.
Determine hazard classification of location; use approved aerial platforms if required.
Report any suspected malfunctions or unsafe conditions immediately.
Charge batteries in a well-ventilated area, free from sparks or flame.
Shut down engine when filling fuel tanks; never start if fuel odour is detected.
Implement means to protect against use by unauthorized persons.