Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.mynightstick.com
INS-XPP5410G-15
Permissible XPP-5410 Flashlight Assembly
APPROVAL No. 20-A140006-0
TESTED FOR INTRINSIC SAFETY IN METHANE-AIR MIXTURES ONLY
WARNINGS:
CLASS I DIV 1 GRPS A-D T3
CLASS II & III DIV 1 GRPS E-G T135C
CLASS I ZONE 0 AEx ia IIC T3 Ga
CLASS I ZONE 0 Ex ia IIC T3 Ga
Ex ia op is I Ma
Ex ia op is IIC T3 Ga
Intertek ITS 13 ATEX27839X
IECEx ITS 14.0036X
&7DPE&
1.5V/Cell AAA Alkaline
0359
ID 4001184
INTRINSICALLY SAFE
SECURITE INTRINSEQUE
I M 1 Ex ia op is I Ma
II 1 G Ex ia op is IIC T3 Ga
The Model XPP-5410 is MSHA approved for use with Energizer (Type E92),
two Energizer (Type EN92), and Duracell (Type MX2400), Duracell
(PC2400), and Duracell (EN92) batteries only. Replace the batteries in
fresh air only and replace all batteries at the same time. Do not mix
batteries from different manufacturers or of different types. The Model
XPP-5410 must not be opened in area where permissibility required.
Conforms to:
ANSI/UL STD 913, ANSI/UL
60079-0, ANSI/UL 60079-11
ANSI/ISA 60079-26
Certified to:
CAN/CSA STD C22.2 No 157
CAN/CSA STD C22.2 No 60079-0
CAN/CSA STD C22.2 No 60079-11
CSA STD C22.2 No 25
Instruction Manual
XPP-5410G
THANK YOU FOR SELECTING THE NIGHTSTICK XPP-5410G
INTRINSICALLY SAFE PENLIGHT!
PLEASE SAVE THESE INSTRUCTIONS
Please read these instructions before using your Nightstick XPP-5410G
Intrinsically Safe Penlight. They include important safety information and
operating instructions.
THE XPP-5410G IS APPROVED FOR USE
WARNINGS - INTRINSICALLY SAFE
Warning: Use only the approved non-rechargeable batteries listed below.
Warning: Do NOT attempt to use rechargeable AAA batteries with this
light.
Warning: To prevent ignition of a hazardous atmosphere, do not open
the lens bezel in the hazardous environment. This task must ONLY be
performed in an area known to be non-hazardous.
Warning: When exchanging batteries, use only ENERGIZER E92, EN92,
OR DURACELL MX2400, PC2400, EN92 BATTERIES.
Warning: To prevent ignition of a hazardous atmosphere, the AAA batteries
must only be exchanged in an area known to be non-hazardous.
Warning: To reduce the risk of explosion, do not mix new non-rechargeable
batteries with used non-rechargeable batteries, or mix non-rechargeable
batteries from different manufacturers.
Warning: Substitution of components may impair intrinsic safety.
SPECIAL INSTRUCTIONS FOR INTRINSIC SAFETY
For personal safety, always confi rm the rating of any known hazardous or
potentially hazardous location where the light is to be used.
BATTERY INSTALLATION
WARNING: In order to maintain the XPP-5410G’s Intrinsically Safe
rating, the only AAA batteries certifi ed for use with this light are the
ENERGIZER E92, EN92, OR DURACELL MX2400, PC2400, EN92
BATTERIES.
Do not attempt to use any other brand or model of AAA batteries with this
light.
Do not attempt to use any type of rechargeable AAA batteries with this
light.
Warning: To prevent ignition of a hazardous atmosphere, do not remove
the lens bezel in the hazardo us environment. This task must ONLY be
done in an area known to be non-hazardous.
Loosen the locking screw located on the side of the lens bezel. NOTE:
Do NOT attempt to completely remove the locking screw. Doing so is not
necessary and may damage the threads. The screw simply needs to be
loosened enough to allow the lens bezel to unscrew.
Unscrew the lens bezel from the housing in a counter-clockwise direction.
Using 2 AAA ENERGIZER E92, EN92, OR DURACELL MX2400,
PC2400, EN92 BATTERIES (make sure both batteries are of the same
type), install the batteries in the light paying close attention to make sure
that the positive end of the batteries point toward the bezel end of the light.
Replace the lens bezel by screwing it onto the housing in a clockwise
direction.
Tighten locking screw. CAUTION: Do NOT over-tighten. Doing so may
damage the threads and impact the light’s Intrinsic Safety.
OPERATION
THE XPP-5410G HAS TWO SEPARATE LIGHTING MODES:
Momentary Flashlight
Constant-on Flashlight
MOMENTARY FLASHLIGHT MODE
Lightly press the tail switch for momentary operation. Release the switch
to turn the light off.
CONSTANT-ON FLASHLIGHT MODE
Press the tail switch until it clicks and then release for constant-on mode.
Press and release the tail switch again to turn the light off.
WARRANTY
LIMITED LIFETIME WARRANTY
Bayco Products, Inc. warrants this product to be free from defects in
workmanship and materials for the original purchaser’s lifetime. The Limited
Lifetime Warranty includes the LEDs, housing and lenses. Rechargeable

Other manuals for NightStick XPP-5410G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NightStick XPP-5410G and is the answer not in the manual?

NightStick XPP-5410G Specifications

General IconGeneral
BrandNightStick
ModelXPP-5410G
CategoryFlashlight
LanguageEnglish

Related product manuals