27
Condenser curve control
Supply air [%]
Condenser temperature [°C]
Filter alarm
From factory, the filter alarm has been set to signal filter replacement every 90 days. You can set the timer to fit the level of pollution
in the area where the ventilation unit has been installed.
If someone in the household has pollen allergies, it is recommended that you install a pollen filter in the outdoor air intake.
> Filter alarm
> Low temp. compr. start Settings:
Standard setting:
Description:
0 -15 °C / Off / 0 15 °C
Off
Here you indicate whether the heat pump is to start up at low
outdoor temperatures, even if heating is not required.
Off means that the function is deactivated.
> Level winter low Settings:
Standard setting:
Description:
Level 1 / Level 2 / Level 3 / Off
Off
Here you specify at what fan speed level you want the ventila-
tion unit to operate at low outdoor temperatures.
Off means that the function is deactivated.
> Temperature winter low Settings:
Standard setting:
Description:
-20 10 °C
0 °C
Here you specify at which outdoor temperature you want the
“Winter low” function to be activated.
ATTENTION
It is important to change the filters regularly and when needed. Dirty filters reduce the efficiency of the ventilation unit
and result in a poorer indoor climate and higher power consumption.
> Days to change Settings:
Standard setting:
Description:
None /30 / 60 / 90 / 180 / 360
90 days
The number of days between filter changes can be set as
required.
36