Fault Cause Remedy
When the cleaner is switched
on the motor buzzer without
starting.
The main voltage is too low
or there is a phase failure
(3 phase model).
The pump is blocked or
frozen.
Incorrect cross-section or
length of the extension lead.
Have the electrical
connections checked.
Pump needs service
(see section ”F”).
Use lead with correct cross
section and length.
The motor switches off.
The overload protection has
been activated due to
overheating or overloading
of the motor.
High pressure nozzle is
dirty.
Check that the main voltage
and the cleaner voltage are
the same.
Switch off the cleaner and
allow it to cool down.
Clean or change the high
pressure nozzle.
Cleaner starts / stops by itself.
Leakage on high pressure
side.
Locate the leak and repair
it.
No detergents drawn in.
Injector in foam sprayer is
dirty or suction hose is
blocked.
Detergent container empty.
Clean.
Top up/change the