Fault Cause Remedy
Pressure drop
- Air in the system.
- High pressure nozzle
blocked / worn.
- Pressure control on the
spray lance is not set
correctly.
- Water inlet temperature
too high.
Vent the system by
operating the spray gun
several times at short
intervals .If necessarily
operate the cleaner for a
short time without the
high pressure hose
connected.
Clean / replace the high
pressure nozzle.
Set the required working
pressure.
See technical data section
”B”.
Pressure
fluctuations
- Lack of water
- Water inlet hose is too long
or its cross-section too
small.
- Lack of water caused by
Blocked/partly blocked water
filter.
- Lack of water because
max. permissible suction
height has not been
heeded.
- Pump sucks in air
(suction mode)
Open water tap.
Use specified water inlet
Hose (Refer to Operating
Manual).
Clean the water filter in the
water connection.
(Never work without water
filter).
See technical data section
”B”
Check that all connections
on the suction side are tight
so no air can be sucked in.
The motor does not start when
the cleaner is switched on.
- The plug is not inserted
properly, i.e. there is no
current.
- The main fuse is switched off.
Check the plug, lead and
switch.
If necessary have them
replaced by a authorized
electrician.
Switch on the main fuse.