System Specicaons
Membrane System w/Tank
Pressure 40-80 psi (275 kPa - 552 kPa)
Temp 40°F - 100°F (4°C - 38°C)
TDS <2000 mg/L
Chlorine <1.0 mg/L
Turbidity <1 NTU
SDI <5
pH 4-8
Performance Specicaons
Feed water must be potable, municipal water. Must
be free of potenal membrane foulants such as Iron,
Hydrogen Sulde and Manganese.
Producon 50 GPD 27 GPD
(189 LPD) (102 LPD)
TDS Rejecon 95% 95%
Recovery
1
35.4% 22.8%
Brine to Product 1.8:1 3.4:1
1
The percentage of the feed water available as reverse osmosis treated
water under normal operang condions.
Tested at 60 psig (4 bar), 500ppm TDS municipal water, 77°F (25°C)
Feed Water Requirements
System - 9.72” W x 13.75” D x 15.38” H ( 24.7 x 34.9 x 39.1 cm), 11 lbs. (5 kg.)
Shipping Box - 14.5"L x 11.25"W x 20"H (36.8 x 28.6 x 50.8 cm), 13.7 lbs. (6.2 kg.)
Dimensions and Weight
A. Product water storage tank
B. Tank valve
C. Tank tubing (3/8” white)
D. Air-gap faucet
E. Drain connecon assembly
F. Drain tubing (3/8” white)
G. Quick connect ng
H. Drain tubing (1/4” black)
I. Faucet tubing (3/8” blue)
J. Four-stage desalinator
K. Feed water tubing (1/4” green)
L. Inlet ng with shut-o
M. Carbon post-lter