System Ac va on and Inspec on
1. Check all tubing connec ons to ensure they are rmly seated. CHECK TO SEE THAT THE CARTRIDGE RETAINER CLIP IS
PROPERLY ENGAGED AND LOCKED. Failure to keep the retaining clip in place will result in accidental leaks and ooding.
2. Open the dispensing faucet at the sink. Close the tank shut-o valve.
3. Open the feed water valve to the system. Observe all tubing and connec ons for several minutes to detect any leaks.
In approximately 5 minutes, (assuming normal feed water pressure) the dispensing faucet should begin dripping.
4. Place a pan or other tempo rary water basin near the drain 'P' trap. Loosen the connector nut holding the 3/8" tube
in the drain saddle connec tor. Pull the tube out of the connector and use the pan to catch any water that may spill. Brine
water should be owing from the tube. Reconnect the tube to the drain saddle and hand- ght en the connector nut.
5. Allow the faucet the run for up to 15 minutes, then close the faucet.
6. Check for leaks at all connec ons.
7. Open the tank shut-o valve.
Ini al Flushing Procedure
1. Before the system can be used for drinking water produc on it must be adequately ushed. Each reservoir tank is
dosed with a small amount of powdered sani zer before shipment, typically a chlorina ng agent, in order to ensure tank
internal cleanliness. Also, the carbon lter cartridge will release a small amount of carbon nes during the rst tankful of
ow. This ushing procedure will allow any sani zer or carbon nes to pass from the system.
2. Ini al tank lling will take approximately one hour (based on average feed pressure). When the tank is full, the water
pressure will have risen to the point where the automa c shut-o valve inside the system will stop the feed ow through
the system. Actua on of the automa c shut-o valve can be determined by either checking for a lack of brine ow to the
drain saddle, or by listening very closely near the dispensing faucet for absence of water ow sound though the air gap.
When the tank has lled for the rst me, it should be le undisturbed for at least 8 hours to ensure proper sani za on.
3. A er 8 hours has elapsed, open the dispensing faucet fully and allow the product water to run out to drain at maximum
ow. The ini al discharge will be dark with the bulk of the carbon par cle wash out. There may also be the scent of chlo-
rinated water from the sani zing agent. When the ow has diminished to a fast drip or small stream, close the dispensing
faucet.
4. Fill and ush the tank at least three mes prior to use. If necessary, repeat un l the chlorina on scent has disappeared.
It is important that the ush be done at maximum ow (e.g. the tank must be full) to assist in rapid wash out. A er this
ushing procedure the system is ready for normal use.
System Ac va on and Flushing

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nimbus Water Systems WaterMaker Five and is the answer not in the manual?

Nimbus Water Systems WaterMaker Five Specifications

General IconGeneral
BrandNimbus Water Systems
ModelWaterMaker Five
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals