EasyManua.ls Logo

Nirvana B50 - Mode Selection (Model C95 Only); Backwash Operations; Changing Display from F° to C°; Resetting the Display

Nirvana B50
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
9.3SELECTIONOFMODE(MODELC95ONLY)
TokeeptheunitintheHEATMODEONLY:Pressthe"SELECT"until"ACH"appearsandpressthearrowkeysuntil
"HEA"appears.Thereafteritremainsonlytochoosethedesiredtemperature.Thisfeatureallowsyoutocontrolthe
minimumleveldesired.Theunitwillheatthewateruntilthedesiredtemperatureisreached.
TokeeptheunitinCOOLINGMODEONLY:Pressthe"SELECT"until"ACH"appearsandpressthearrowkeysuntil
"COL"appears.Thereafteritremainsonlytochoosethedesiredtemperature.Thisfeatureallowsyoutocontrolthe
desiredmaximumdegree.Theunitwillcoolthewateruntilthedesiredtemperatureisreached.
ToputtheunitinAUTOMODE:Pressthebutton"SELECT"until"ACH"appearsandpressthearrowkeysuntil"AU"
appears.Thereafteritremainsonlytochoosethedesiredtemperature.Thisfunctionkeepswateratdesired
temperature.Inotherwords,itwillheatorcoolwateruntilthewatertemperaturereachesthedegreeselected.
BACKWASHOPERATIONS
1. Carryoutthebackwashprocedureasfollows:
2. TurnOFFthepowertothepump(withpowersupplyor(FIL=OFF,POL=OFFandSPAOFF)).
3. PreparethesystemforbackwashandpowerONthepump(withpowersupplyor(FIL=ON)).
4. ThecirculatingpumpwillgoONandthecontrollerwillnotcheckfor5minutesifwaterflowispresentatthe
flowswitch.
5. Youwillhave5minutesofuninterruptedwaterflowtodothebackwash.
6. Stopthecirculatingpump(usethepowersupplyorFIL=OFF).
Normally,whenthecirculatingpumpisrequiredforthisoperationandthereisnowaterflowdetectedatthecontrol,
thepumpwillautomaticallyturnOFF.Thisprocedurewillgivea5minuteperiodofuninterruptedwaterflowbefore
thecirculatingpumpturnsOFF.
CHANGINGTHEDISPLAYFROMTO
FactorydefaultsareinF°.
PressandholddowntheSETkeyuntilthemessagePOLappears.
PresstheSETkeyuntilF_Cisdisplayed.
Pressthe↑keytoselect°Forpressthe↓keytoselect°C.
RESETTINGTHEDISPLAY
If a flashing PLE or CSE error message is displayed, hold down the SET key until the error message is no longer
displayed(approx.4seconds).Thecontrolwillberesettothefactorydefault.
Reprogramallthesettings.
DEICINGOPERATION
Duringtheevaporatorcoildeicingcycle,FSwillbedisplayedtoindicatethattheunit isdeicing.Duringthistime,the
fanisonandthecompressorisnotinoperation

Other manuals for Nirvana B50

Related product manuals