8 Cleaning
Remove the baeries from the device prior to cleaning.
Wipe the device with a dry cloth.
Do not clean the product using corrosive cleaning agents.
Protect the device from penetraon of water or other
liquids.
Do not immerse the device in water or other liquids.
9 Repair
The components of the mulmeter measuring circuits
do not contain any user-serviceable parts, except for the
F1 and F2 fuses (see fuse replacement). Do not repair
the device yourself. Always have a repair professional
repaired.
Replacing fuses
NOTICE! Risk of damage!
Make sure that all circuit parts, circuits and
components, as well as all other measuring
objects are completely dead and discharged.
9.1 According to the instrucons described in point “7.1
Baery inseron and change”, open the housing of the
mulmeter and disconnect it from the 9V baery.
9.2 Remove the defecve fuse F1: F 250 mA / 300 V or
F2: F 10 A / 300 V.