Thank you for choosing a NIVELCO instrument.
We are sure that you will be satisfied throughout its use.
1. APPLICATION
The NIVOPRESS submersible hydrostatic level transmitter is applicable for the continuous level measurement of clean
or chemically faintly contaminated liquids in bored well, open reservoirs and tanks. The NIVOPRESS is easy to install in
already existing tanks and in deep bored well and is especially recommended for controlling of submersible pumps.
2. TECHNICAL DATA
Type NPK NPH
Ranges 0 …1, 2, 5 etc max 200 m. water head (see order codes)
Overload allowed
For models with measuring limit below 20 m w. h. 2 x measuring limit
For models with measuring limit over 20 m w. h. 1.5 x measuring limit
Output 4 … 20 mA 2-wire 0 … 10V 3-wire
Operating voltage 9 to 30 V DC 18 to 30 V DC
Maximum load resistance
R
s
= (U
s
- 9 V) / 0.02 A
U
s
= voltage of the power supply
5 k
Current < 6 mA
Accuracy (FSO)
± 0.5 %
Zero drift
± 0,1 mA 80 mV
Temperature coefficient
± 0.1 %/ 10K ± 0.2% / 10 K
Operating temperature
-10 °C to +60 °C
for special request +75 °C
Ingress IP 68
Cable cross secion 0.34 mm
2
Cable coating
Polyurethane 7mm
Cable length up to 300 m according to the order
Probe size
22 x 215 mm
Mass probe: 0.2 k g cable: 0.06 kg/m
Wetted parts
Sensor: stainless steel 316L
Probe stainless steel 1.4571
Cable coating: polyurethane
Sealing: VITON
Protecting cap: ABS
Cable mounting plate NAA-103
Applicable With cable length up to150 m
Operating temperature -10 °C to +45 °C
Dimensions 110 x 110 mm
Cable terminal box NAA-101
Dimensions 139 x 119 x 70 mm
Ingress IP 65
Operating temperature –40 °C to +65 °C
Material Plastic
Cable gland
ASM16 ( 5 to 10mm)
Electric connection Terminal block for cable with max cross section of 2.5 mm
2
Cable terminal box with over voltage protection NAA-102 (for 2-wire models only)
Voltage clipping 33 V
pp
Serial resistance
13 ohm ±10 %
Leakage current
10 µA
Other data Same as with NAA101
Over voltage protection unit OVP12/33 and OVP32/33
Electric data Same as with NAA102
OVP12/33
OVP32/33 DIN rail mount
Ingress protection IP 54 IP 20
Dimensions 72 x 42 x19 mm 62 x 65 x 18 mm
2.1 A
CCESSORIES
Optional
(to be ordered)
User’s Manual Cable mounting plate NAA 103
Guarantee sheet Cable terminal box NAA 101
Cable terminal box with OVP12/33 NAA 102
DIN rail mount over voltage protection OVP32/33
2.2 O
RDER
C
ODE
NIVOPRESS N P - 2 -
Output Code Range ** Code Cable length Code Cable length Code
0 … 1 m water head 1 10 m 1 1 m 1two-wire
4 … 20 mA
K
0 … 2 m water head 2 20 m 2 2 m 2
0 … 5 m water head 3 30 m 3 3 m 3three-wire
0 … 10 V DC
H
0 … 10 m water head 4 40 m 4 4 m 4
0 … 20 m water head 5 50 m 5 5 m 5
0 … 50 m water head 6 60 m 6 6 m 6
** Different span within the range
on special request.
0 … 100 m w. head 7 70 m 7 7 m 7
0 … 200 m w. head 8 80 m 8 8 m 8
90 m 9
up to 100 m
9 m 9
100 m A 0 m 0
200 m B 10 m 1
300 m C : :
over
100 m
90 m 9
USER’S MANUAL
Manufacturer:
NIVELECO Process Control Co.
H-1043 Budapest, Dugonics u. 11.
Tel: (36-1) 369-7575 Fax: (36-1) 369-8585
e-mail: sales@nivelco.com http://www.nivelco.com
2.3 D
IMENSIONS
in mm
NIVOPRESS NP probe
215
22
protection
cap
St.St.
cartridge
breathing
cable
7
Cable mounting plate NAA103
mounting
plate
breathing cable
Tart ó
1
1
0
110
15
30
1
5
10
6,3
7
,
5
breathing cable
Cable terminal box NAA101/NAA102
139
airing
1
1
9
80
ø4,5
Conduit opening Mounting
Question and Answer IconNeed help?