trash is unlawful under state and federal environmental laws and regulations. Always take the product to your local battery recycling
center. Retrofit. Lithium-ion batteries weigh substantially less than lead-acid batteries of comparable capacity. Some equipment is
designed to utilize the weight of lead-acid batteries to achieve weight distribution. Using the product as a replacement battery could
impact the weight distribution of the equipment. Understand the consequences of modified weight distribution and ensure safe weight
distribution. You assume all responsibility and liability for any damages, injuries, or accidents that may occur due to degraded stability.
Charging. The product is a 12-volt lithium-ion battery. Do not use a charger that utilizes a pulse charge or a desulfation feature. For
optimal performance, we recommend only using the 12-volt lithium mode on NOCO Genius chargers. If using a third-party charger, it
must be compatible with 12-volt Lithium Iron Phosphate (LiFePO4) batteries with a charging voltage of 14.6-volts, and be certified under
one or more of the following standards: IEC60601, UL1236, RCM, PSE or CE (LVD, EMC). Be cautious of using low-quality chargers,
as they may present a severe electrical risk that can result in injury to person and property, as well as shorten the life of the product
and cause the product to malfunction. NOCO is not responsible for the user’s safety when using accessories or chargers that are not
approved by NOCO. During charging, if the battery becomes excessively warm, deforms, swells, or emits smoke or odor, discontinue
use immediately and contact support. Connections. Make sure all connections to the product are secure. Use 70-90 inch-pounds of
torque to secure the connections properly. Loose connections may cause reduced performance and increased heat due to resistance
that may cause the melting of the enclosure or potentially a fire. Medical Devices. The product may emit electromagnetic fields.
The product contains magnetic components that may interfere with pacemakers, defibrillators, or other medical devices. Consult with
your physician before use if you have any medical device. If you suspect the product is interfering with a medical device, stop using
the product immediately, and consult your physician. Cleaning. Disconnect and remove the product before cleaning. Immediately
dry the product if it comes in contact with liquid or any contaminant. Use a soft, lint-free (microfiber) cloth. Do not use a pressure
washer to clean the battery. Explosive Atmospheres. Obey all signs and instructions. Do not operate the product in any area with
a potentially explosive atmosphere, including fueling areas or areas which contain chemicals or particles such as grain, dust, or metal
powders. High-Consequence Activities. Do not use the product where the failure of the product could lead to injury, death, or
severe environmental damage. Radio Frequency Interference. This product complies with regulations governing radio frequency
emissions. Such emissions from the product may negatively aect the operation of other electronic equipment, possibly causing them
to malfunction.