EasyManua.ls Logo

NoiseKen INS-4020 - User Manual

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTRUCTION MANUAL
IMPULSE NOISE SIMULATOR
MODEL INS-4020/4040
NOISE LABORATORY CO., LTD.
Editio n 2 . 0 3
AE B 0 03 1 9- 00E - 1 D

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NoiseKen INS-4020 and is the answer not in the manual?

Summary

IMPORTANT SAFETY PRECAUTIONS

APPLICATION FORM FOR INSTRUCTION MANUAL

PREFACE

BASIC SAFETY PRECAUTIONS

Warning signs and their meanings

Explains symbols for HV voltage, caution, and protective earth.

Basic safety precautions

Crucial rules for pacemakers, explosive areas, grounding.

When warning label is missing

Instructions for handling missing or damaged warning labels.

Restrictions to comply with CE marking requirements

Details CE compliance for voltage, installation, pollution.

Coaxial connectors used for this product

Info on NMHV connectors and compatibility.

GENERAL DESCRIPTION

Features

Highlights key capabilities: pulse generation, width, voltage, sync.

Pulse generation principle

Explains internal circuitry and components for pulse generation.

For perfect matching

Describes termination resistors' role in square wave pulses.

Range of settings for pulse and other parameters

Lists adjustable parameters and their ranges.

INCLUDED ACCESSORIES

CONTROLS AND DISPLAY FUNCTIONS

Front panel connecters and terminals

Details all connectors and terminals on the front panel.

Front panel controls and displays

Explains buttons, dials, and displays on the front panel.

Rear panel

Describes AC INPUT, PE, EUT LINE INPUT, fan, and serial number.

OPERATION

Operating precautions

Essential precautions for placement and connections.

Turning ON and OFF power

Instructions for powering on/off, EUT supply safety notes.

Setting the pulse width

How to set pulse widths using coaxial cable connections.

Connecting termination resistance

How to connect termination resistance for pulse output.

Select injection line

Guides on selecting EUT line (L1, L2, PE) for pulse injection.

EUT line input connection

Connecting EUT power supply, emphasizing isolation transformer.

Mount and dismount Outlet panel

Procedures for attaching and removing the outlet panel.

EUT connection

Guidelines for connecting the EUT to the simulator.

Connection of signal ground (SG) terminal

How to connect SG terminal for common mode tests.

Operation in PHASE mode

Pulse generation synchronized with AC frequency and phase control.

Operation in VARIABLE mode

Pulse generation independent of AC frequency via pulse period.

Operation in 1 SHOT mode

Generating single pulses by pressing the 1 SHOT button.

Operation in EXTernal Trigger mode

Using external signals or switches for synchronization/control.

Stop the unit

Procedures for stopping pulse generation and safety.

OPERATION FOR WIDE APPLICATION

VOLTAGE ramp setting

Setting parameters for automatic voltage ramping.

VOLTAGE ramp test run

Executing the automatic voltage ramp test.

VARIABLE ramp setting

Setting parameters for automatic pulse period ramping.

VARIABLE ramp test run

Executing the automatic pulse period ramp test.

PHASE ramp setting

Setting parameters for automatic phase angle ramping.

PHASE ramp test run

Executing the automatic phase angle ramp test.

Combined ramp mode

Combining ramp modes for complex tests.

Remote START and STOP

Controlling test start/stop remotely via EXT TRIG.

Memory function

Saving and recalling current settings.

Terminating resistor

Explains resistors and applications for voltage correction.

TEST SET-UPS AND ENVIRONMENT

Precautions for use

Reminds users to follow safety precautions before testing.

Test parameters

Lists parameters to be considered and evaluated during testing.

Coupling modes

Overview of different coupling modes for AC/DC equipment.

Test set-ups

Recommended configurations for test tables, ground planes, insulation.

Test set-up

Detailed setup procedures for common and normal mode tests.

SPECIFICATIONS

Product Specifications

Table detailing output voltage, pulse width, repetition modes, power specs.

Consumable parts

Identifies consumable components like cables and relays.

WAVEFORM CHECK

Instrument required

Lists necessary equipment for waveform checks.

Oscilloscope settings

Recommended settings for the oscilloscope during waveform analysis.

Settings on this unit

Specifies the unit's settings for performing a waveform check.

Checking the waveform

Step-by-step guide on verifying output waveform.

RELAY UNIT

2 kV relay unit and 4 kV relay unit

Distinguishes relay units for INS-4020/4040.

How to replace the relay unit

Procedure for safely replacing the mercury relay unit.

PHASE ANGLE CORRECTION

Equipment required

Lists equipment for phase angle correction.

Connections and settings

Outlines connection steps and initial settings for correction.

Setting up Correcting phase angle

Step-by-step adjustment for accurate phase angle correction.

Releasing Phase Angle Correction

Procedures to cancel or reset phase angle correction.

WARRANTY

Servicing Terms

Defines terms and conditions for product servicing by the company.

MAINTENANCE

General maintenance instructions

User-level maintenance, cleaning, and safety.

NOISE LABORATORY SUPPORT NETWORK

Troubleshooting and Contact Information

Guidance on reporting symptoms and contacting support.

Limited warranty

Scope

Warranty applies only to products made by the Company.

Period

Defines warranty duration as one year from delivery.

Exclusions

Lists items and conditions not covered by the warranty.

NoiseKen INS-4020 Specifications

General IconGeneral
BrandNoiseKen
ModelINS-4020
CategoryRecording Equipment
LanguageEnglish

Related product manuals