LRK-2 / 3 LGA component rework kits 1 & 2
Rework procedure
Due to the large mechanical tolerance of the power amplifiers the following procedure is nec-
essary:
1 Put the power amplifier into the MJS-76 rework jig. The PA should be placed in
the best fit location which is determined by placing the PA in the largest location
first, and if this is to large, re-position it to the next location. This should be car-
ried out until the best fit location is found.
Type designator
Description Part code
LRK-2 (0273645) Kit 1
MJS-76 LGA Re-work
Jig
0770417
SES-2 Stencil 0770415
SPS-2 Spreader 0770471
LRK-3 (0273646) Kit 2
SES-2 Stencil 0770415
SPS-2 Spreader 0770471