5 Parameter
BU 0600 en-2319 79
P002 Display factor S
Setting range
0.01 … 9999.99
Factory setting { 1 }
Description
The selected operating value in parameter P001 "Display selection" is multiplied by
the scaling factor in P000 and displayed in the "Operating display".
It is therefore possible to display system-specific operating values e.g. throughput
quantity.
P003 Supervisor code
Setting range
0 … 9999
Factory setting { 1 }
Description
The scope of the visible parameters can be influenced by setting the supervisor code.
Note
Display via NORDCON
If parameterisation is carried out with the NORDCON software, the settings 2 ... 9999
the settings are as for the 0 setting.
Setting values
Value Meaning
0 Supervisor mode Off
The supervisor parameters are not visible.
1 Supervisor mode On
All parameters are visible.
2
Supervisor mode Off
The supervisor parameters are not visible.
P004 Password S
Setting range - 32768 … 32767
Factory setting
{ 0 }
Description
Entry of the password from P005 to unlock all visible, editable parameters.
Note
The value which is entered here is lost when the control board / the frequency inverter
is switched off. Password protection is active again.
P005 Change password S
Setting range
-32768 … 32767
Factory setting { 0 }
Description
Specification of a password to protect the setting values of editable parameters from
unauthorised changes. Password protection can be temporarily suspended via P004.
Note
The password is generally cancelled with setting "0" in P005.