  • P
    Peter JohnsonAug 9, 2025
    What to do if NORD Industrial Equipment has vibrations when switching on?
    • M
      Melanie HillAug 9, 2025
      If your NORD Industrial Equipment experiences shocks and vibrations when you switch it on, it could be due to a defective motor coupling, loose gear unit mounting, or a defective rubber element. You should replace the elastomer gear rim, tighten the motor and gear unit fastening bolts, and replace the rubber element.
  • P
    pricedavidAug 14, 2025
    Why is oil escaping from the pressure vent of my NORD Industrial Equipment?
    • B
      Barbara CarlsonAug 14, 2025
      Oil escaping from the pressure vent of your NORD Industrial Equipment can be due to an incorrect oil level, incorrect or contaminated oil, or unfavorable operating conditions. You should change the oil and consider using an oil expansion tank.
  • R
    Raymond SanchezAug 19, 2025
    What to do if the gear unit of my NORD Industrial Equipment becomes too hot?
    • J
      Jennifer OnealSep 12, 2025
      If the gear unit of your NORD Industrial Equipment is overheating, it may be due to unfavorable installation conditions or damage to the gear unit. Please consult NORD Service for assistance.
  • A
    Ashley GreenAug 25, 2025
    What to do if oil is escaping from the gear unit or motor of my NORD Industrial Equipment?
    • J
      Julian ContrerasAug 25, 2025
      If oil is escaping from the gear unit or motor of your NORD Industrial Equipment, it is likely due to a defective seal. Consult NORD Service to resolve this issue.
  • K
    kevin61Aug 29, 2025
    What to do if the drive shaft of my NORD Industrial Equipment doesn't rotate even when the motor is running?
    • O
      Olivia HoffmanAug 29, 2025
      If the drive shaft of your NORD Industrial Equipment does not rotate while the motor is running, it could be caused by a fracture in the gear unit, a defective motor coupling, or shrink disc slippage. Consult NORD Service for assistance.
  • C
    Carl SanchezSep 3, 2025
    Why is the pressure at the pressure safeguard too low in my NORD Industrial Equipment?
    • C
      Carl MillerSep 3, 2025
      If the pressure at the pressure safeguard is too low in your NORD Industrial Equipment, it could be because the pump is not delivering any oil or there is a leakage in the piping. Check the pump and the pipes to identify and fix the issue.