Do you have a question about the Nordic DELTACO SH-AC01 and is the answer not in the manual?
| Connectivity | Wi-Fi |
|---|---|
| App Support | Yes |
| Power Supply | 220-240V, 50Hz |
| Functions | Cooling, Fan |
| Cooling Capacity | 9000 BTU |
| Power Consumption (Heating) | 800W |
Covers electrical safety, placement, cable management, and general operation precautions.
Addresses cable damage, installation standards, user age, cleaning, chemical use, and flammable substances.
Covers storage, operation, ventilation, and qualified personnel for R290.
Covers transport regulations, marking, disposal of equipment, and storage of packed items.
Details servicing information, area checks, work procedures, general work area safety, and refrigerant checks.
Checks for installations using flammable refrigerants, including charge size, ventilation, and labelling.
Safety checks for electrical components, capacitor discharge, exposed wiring, and earth bonding.
Precautions for repairing sealed components, including power disconnection and casing integrity.
Guidelines for working on intrinsically safe components, including voltage limits and suitable parts.
Checks cabling for wear, corrosion, pressure, vibration, and environmental effects.
Prohibits ignition sources when searching for or detecting refrigerant leaks.
Covers electronic detectors, leak fluids, and refrigerant recovery for brazing.
Steps for accessing the circuit: remove refrigerant, purge, evacuate, and flush with OFN.
Ensures no contamination, uses short hoses, keeps cylinders upright, and earths the system.
Pre-decommissioning checks, electrical isolation, equipment, PPE, supervision, and recovery conformity.
Procedures for pumping down, using manifold, weighing cylinders, and operating recovery machines.
Do not overfill cylinders, exceed pressure, or charge recovered refrigerant into other systems.
Equipment must be labelled as decommissioned and emptied of refrigerant, dated and signed.
Safe removal and transfer of refrigerant into appropriate cylinders with correct labeling and condition.
Evacuate compressor oil to remove refrigerant before returning it.
Information on fluorinated gases, quantity, CO2 equivalent, and requirement for certified technicians.
Lists and identifies key parts of the portable A/C unit with reference numbers.
Details the functions of the timer, fan speed, mode, sleep, swing, and temperature buttons.
Explains Dehumidifier, Frost protection, Overflow protection, Automatic defrosting, and Compressor protection.
Keep upright for 2 hours, place on flat surface, avoid humid environments.
How to connect the ventilation pipe to adapters and the device's air ventilation.
Instructions for mounting the window kit horizontally or vertically to the window frame.
Specifies minimum 50 cm distance between the product and walls or other objects.
Length must be 280-1500mm. Do not use extensions or block the outlet.
Turn off, unplug, clean with damp cloth. Avoid chemicals. Clean filters every two weeks.
Steps for removing, cleaning, and re-installing filters with warm water and mild detergent.
Empty water, dry unit, disconnect, protect from dust, store in dry place, remove batteries.
Details manual drainage and continuous drainage setup.
Covers no power, 'FULL' indicator, ambient temperature, and incorrect temperature settings.
Addresses direct sunlight, open doors/windows, dirty filters, and blocked air inlet/outlet.
Covers noise from placement and compressor overheat protection.
Checks remote function and explains 'E1'/'E2' error codes for sensor issues.
Download, install, create account, add device, connect to power, activate Wi-Fi, confirm network.
Details rated voltage, fuse type, and frequency.
Provides website for more product information.
Carton can be used for storage. Dispose of packing material by recycling.
Product must not be treated as household waste; return to collection point for recycling.