Instruction Sheet 46-75
Page 8
2300 Retrofit
23. Run the Rechner Sensor lead through the conduit and plug
into the bottom of the Rechner Controller.
24. Remove the hood and chute assembly from the unit and dis-
card.
25. Set the new chute assembly on the unit. Place the new hood in-
side the chute assembly.
26. Remove the Pump Enclosure and discard.
27. Secure the sensor bracket over the knock-out hole on the unit.
(Located under the pump tower).
28. Remove the electrical enclosure on the unit. Install the PM1
Board into the unit. (See Installlation instructions on page 10)
29. Remove the knock-out provided in the base and connect the
PM1 conduit to the base of the unit. Connect the PM1 leads (#7
and #4B) to the PM1 board. (See instructions on page 10)
30. If your unit does not have a knock-out provided, use the follow-
ing procedure.
a. Remove the input power terminal.
b. Drill a .875” hole in the bottom of the unit as shown
in Figure 7.
I
INPUT
+---TERMINAL
BLOCK
DRILL -875”
Figure 7 - Position of the Conduit Hole for the PM1
Issued l/89
ONORDSON CORPORATION 1988
All Rights Reserved
Pub. No. 108 428A