Temperature Part
See Figure 3.
WARNING: The temperature prescribed by
the material manufacturer is decisive. Do not
exceed the maximum operating temperatures
of the system and the heated system
components.
NOTE: Nordson Corporation assumes no guarantee
and/or liability for damage caused by incorrect
temperature settings.
Switching on/off immediate temperature setback
Switching ON: Press key 10; SPL blinks in display 4 and the
LED in the key lights.
Switching OFF: Press key 10 or wait until the setback
period has expired. The temperature setback does not
automatically end if the setback period is longer than
9.99 hours.
Note: The temperature setback can also be switched on via
the XS 2 interface. When the temperature setback is
switched on, SPL blinks in displays 4 and 30 (Figure 2). A
setback period is ineffective in this case.
Note: The Automatic Temperature Setback After Motor
Standstill is ended by pressing key 25 (Figure 2) on the
motor part. Press key 25 for approx. 2 seconds.
Setting temperature setpoint and parameters
Hold down key 16 and increase value with key 11 or
decrease with key 12. Pressing once changes the value by
1, holding the key changes the value faster.
The LED in key 16 is lit when adjustable parameters are
shown in displays 3, 4 and 5. The following parameters can
be adjusted:
Switching channels / selecting parameters
Press key 13 or 14 until the desired channel appears
in display 3.
When the highest channel that is switched on is
exceeded, the following displays/parameters can be
called up:
C
F
3
4
5
10
1112
13
14
16
Displays
Refer to Overview of Displays and Diagnosis
Program sections in the Control System
manual.
Decimal point
Lit when the displayed
channel is heating.
°C / °F status display
Temperature setpoint
SPL Temperature setback value
h SPL Temperature setback period
Lo Under temperature value
Hi Over temperature value
°C / °F Temperature unit
CLr Return parameter to factory setting
SPL Temperature setback value
h SPL Temperature setback period
Lo Under temperature value
Hi Over temperature value
OFF Over temperature shutdown
SE Service display (sensor type)
°C / °F Temperature unit
CLr Return parameter to factory setting
If no other key is pressed within 120 sec., these
displays return to the reference channel or the
channel with the lowest number.
Figure 3 Temperature Part