Owners Manual/Installation Instructions
CMF2 80-PG Convertible (65, 75, and 85 KBTU/H Inputs),
CMF2 80-PO Convertible (65, 75, and 85 KBTU/H Inputs)
Counterfl ow Gas or Oil Heating Appliance
Read all instructions carefully before beginning the installation. Read all labels and tags on
the furnace carefully and follow all precautions outlined on those labels and tags.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity
of this or any other appliance.
WARNING:
Improper installation, alteration,
service or maintenance can cause
injury or property damage. Refer to
this manual for assistance or consult
a qualifi ed installer, service agency,
or the gas supplier for additional
information.
FOR YOUR SAFETY
WHAT TO DO IF YOU
SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
If you cannot reach your gas supplier,
call the fi re department.
GENERAL
CMF2 furnaces are high quality, direct vent
furnaces used for manufactured housing,
recreational vehicle, and residential
applications.
These furnaces are offered in either power gas
(designated by PG) or power oil (designated
by PO) models. The power gas models are
designed for operation with either natural or
propane (LP) gas.
The CMF2 series is convertible from power oil to
power gas, and vice versa. Furthermore, the fi ring
rate of the CMF2 80 Convertible Series can be
changed using a certifi ed NORDYNE conversion
kit fi eld-installed by a qualifi ed service technician.
Refer to the “Firing Rate Conversion” section
later in these instructions for more information
on the fi ring rate change.
These furnaces are certifi ed to the UL307
standards (UL 307A for oil models; UL 307B for
gas models), and can be installed in a variety of
applications, as shown in Table 1. This furnace is
not to be used for temporary heating of buildings
or structures under construction.
WARNING:
This furnace must be installed by a qualifi ed
installing agency and in accordance with
applicable local codes and ordinances that
govern this type of equipment. Failure to
properly install the furnace, base assembly,
and venting system as described herein
may damage the equipment and/or the
home, can create a fi re or asphyxiation
hazard, violates U.S. listing requirements,
and will void the warranty. This furnace is
NOT approved for installation with split
system air conditioning. Use a NORDYNE
packaged air conditioning system.
Rated
BTUH
CMF2-PG
80 CONV.
CMF2-PO
80 CONV.
Input 75,000 75,000
Output 56,000 60,000

Table of Contents

Questions and Answers

  • A
    Adrian CarrilloAug 18, 2025
    How to troubleshoot Nordyne CMF2 80-PG Convertible Gas Heater burner that does not start?
    • K
      Kathryn CannonAug 18, 2025
      If the burner of your Nordyne Gas Heater doesn't start when there's a call for heat, begin by checking the electrical supply to the furnace and ensuring the furnace door switch is in the 'on' position. Verify that there's a line voltage of 115 VAC at the oil primary control. If the indicator light is on when the burner is off and there's no call for heat, the cad cell may be detecting stray light, or the cad cell or controller might be defective. Try jumpering the T to T terminals on the primary control. If the burner starts, inspect the thermostat or limit wiring connections for faults. If the burner still doesn't start, turn off the power and check all wiring connections. As a last resort, replace the R7184 control.
  • D
    Daniel WilliamsAug 27, 2025
    What to do if Nordyne Gas Heater burner will not start and indicator light continues to flash?
    • D
      Dennis CarpenterAug 27, 2025
      If the indicator light continues to flash when your Nordyne Gas Heater burner will not start, wait for 60-70 seconds. If it continues to flash after this time, replace the primary control.
  • A
    Adam CortezSep 3, 2025
    How to check Cad Cell Resistance on Nordyne CMF2 80-PG Convertible?
    • M
      megan54Sep 3, 2025
      To check the Cad Cell Resistance on your Nordyne Gas Heater, press and release the button during the run mode. The indicator light will flash to indicate the cad cell resistance. For proper burner operation, ensure the cad cell resistance reading is not over 1600 Ohms.
  • R
    Ryan BlackwellNov 11, 2025
    What to do if Nordyne CMF2 80-PG Convertible Gas Heater burner starts then locks out?
    • J
      Joy OlsenNov 11, 2025
      If your Nordyne Gas Heater burner starts but then locks out with the indicator light flashing at ½ second intervals, first reset the primary control. If the indicator light stops flashing but ignition remains off, the primary control could be defective, and if line voltage is present at the ignitor terminals with no ignition, the ignitor is likely defective and needs replacement. If the indicator light stops flashing, the burner turns on, but the control locks out again, inspect the cad cell; if it's okay, replace the primary control. Also, ensure the control isn't in restricted mode; if it is, reset it. If not in restricted mode, replace the R7184. Check that the cad cell sighting has a clear view of the flame, and verify the cad cell resistance. If the indicator light is off, inspect the...

Nordyne CMF2 80-PG Convertible Specifications

General IconGeneral
Model NumberCMF2 80-PG
TypeConvertible
Heating Capacity80, 000 BTU
Efficiency80% AFUE
Fuel TypeNatural Gas or Propane
Thermostat CompatibilityStandard