Owners Manual/Installation Instructions
CMF2 80-PG Convertible (65, 75, and 85 KBTU/H Inputs),
CMF2 80-PO Convertible (65, 75, and 85 KBTU/H Inputs)
Counterfl ow Gas or Oil Heating Appliance
Read all instructions carefully before beginning the installation. Read all labels and tags on
the furnace carefully and follow all precautions outlined on those labels and tags.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity
of this or any other appliance.
WARNING:
Improper installation, alteration,
service or maintenance can cause
injury or property damage. Refer to
this manual for assistance or consult
a qualifi ed installer, service agency,
or the gas supplier for additional
information.
FOR YOUR SAFETY
WHAT TO DO IF YOU
SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
If you cannot reach your gas supplier,
call the fi re department.
GENERAL
CMF2 furnaces are high quality, direct vent
furnaces used for manufactured housing,
recreational vehicle, and residential
applications.
These furnaces are offered in either power gas
(designated by PG) or power oil (designated
by PO) models. The power gas models are
designed for operation with either natural or
propane (LP) gas.
The CMF2 series is convertible from power oil to
power gas, and vice versa. Furthermore, the fi ring
rate of the CMF2 80 Convertible Series can be
changed using a certifi ed NORDYNE conversion
kit fi eld-installed by a qualifi ed service technician.
Refer to the “Firing Rate Conversion” section
later in these instructions for more information
on the fi ring rate change.
These furnaces are certifi ed to the UL307
standards (UL 307A for oil models; UL 307B for
gas models), and can be installed in a variety of
applications, as shown in Table 1. This furnace is
not to be used for temporary heating of buildings
or structures under construction.
WARNING:
This furnace must be installed by a qualifi ed
installing agency and in accordance with
applicable local codes and ordinances that
govern this type of equipment. Failure to
properly install the furnace, base assembly,
and venting system as described herein
may damage the equipment and/or the
home, can create a fi re or asphyxiation
hazard, violates U.S. listing requirements,
and will void the warranty. This furnace is
NOT approved for installation with split
system air conditioning. Use a NORDYNE
packaged air conditioning system.
Rated
BTUH
CMF2-PG
80 CONV.
CMF2-PO
80 CONV.
Input 75,000 75,000
Output 56,000 60,000

Table of Contents

Questions and Answers

Summary

INSTALLATION REQUIREMENTS

Requirements and Codes

Installer must comply with all applicable codes and regulations for appliance installation.

Combustion Air and Ventilation Requirements

Ensure adequate combustion air and ventilation as per codes and furnace type.

Venting Requirements - Residential Installations

For residential, use SRJ roofjack or existing chimney, following codes and instructions.

UNIT INSTALLATION

MA-200 Base Installation

Instructions for installing the MA-200 base for CMF2 series furnace.

MA-100 Universal Base Installation

Details for installing the MA-100 universal base for CMF2 series furnace.

FUEL CONNECTIONS

Gas Piping Requirements - PG Series Only

Requirements for sizing and installing gas piping for PG series.

Oil Piping Installation - PO Series Only

Recommendations for oil piping installation for PO series.

WIRING DIAGRAM

ELECTRICAL WIRING

LIGHTING AND OPERATING INSTRUCTIONS FOR CMF2 PG DIRECT IGNITION GAS BURNERS

Operating Instructions for PG Direct Ignition Burner

Step-by-step instructions for operating the PG direct ignition burner.

Natural Gas to LP Conversion

Procedure for converting the appliance from natural gas to LP gas.

LIGHTING AND OPERATING INSTRUCTIONS FOR CMF2 PO OIL BURNERS

Start-Up Procedure

Steps to initiate the start-up procedure for oil burners.

FIRING RATE CONVERSION

How to adjust the furnace firing rate using a conversion kit.

Overview

This document describes the CMF2 80-PG Convertible (65, 75, and 85 KBTU/H Inputs) and CMF2 80-PO Convertible (65, 75, and 85 KBTU/H Inputs) counterflow gas or oil heating appliances, including their installation, operation, and maintenance.

Function Description:

The CMF2 series furnaces are high-quality, direct-vent heating appliances designed for use in manufactured housing, recreational vehicles, and residential applications. They are available in either power gas (PG) or power oil (PO) models. The power gas models are designed to operate with either natural gas or propane (LP) gas. A key feature is their convertibility between power oil and power gas, and their firing rate can be adjusted using a certified NORDYNE conversion kit installed by a qualified service technician. These furnaces are certified to UL307 standards (UL 307A for oil models; UL 307B for gas models). They are not approved for installation with split system air conditioning; NORDYNE packaged air conditioning systems should be used instead. The furnace is not intended for temporary heating of buildings or structures under construction.

Important Technical Specifications:

  • Firing Rates: Convertible between 65,000, 75,000, and 85,000 BTU/hr inputs.
  • 75,000 BTUH Input (PG/PO): Output 56,000 BTU/H (PG), 60,000 BTU/H (PO).
  • Fuel Type: Power Gas (PG) models use natural gas or LP gas; Power Oil (PO) models use No. 2 fuel oil (No. 1 may be used in low temperatures).
  • Electrical: 120 Volt, Single Phase / 60 Hz.
  • Combustion Air: Can be drawn from outside (direct vent) or conditioned space (special CB-200A cottage base installations only).
  • Venting: Direct vent system required for most applications, typically using NORDYNE SRJ series roofjacks. Can also vent through existing chimneys for residential applications, adhering to specific material and sizing requirements (e.g., capable of withstanding 700°F, vertical chimney, connecting pipe slope of at least 45 degrees, total sloping pipe length not exceeding 6 feet).
  • Clearances to Adjacent Materials (Minimum):
    • Sides: 0" (Closet/Alcove)
    • Back: 0" (Closet/Alcove)
    • Front: 6" (Closet), 18" (Alcove) - with specific requirements for louvered doors if less than 6" front clearance.
    • Top: 17" (Closet/Alcove)
    • Vent: 6" (Closet/Alcove)
    • Duct within 3' from Furnace: 1/4" (Closet/Alcove)
    • Plenum: 1" (Closet/Alcove)
    • Roof Jack Barrel: 0" (Closet/Alcove)
  • Gas Piping (PG Series): Sized according to ANSI Z223.1/NFPA 54. Inlet gas line pressure: 5-7 in WC (natural gas), 11-13 in WC (LP gas). Manifold pressure: 3.5 in WC (natural gas), 10.0 in WC (LP gas).
  • Oil Piping (PO Series): 3/8" O.D. copper tubing for fuel line. One-line system recommended for vertical lift up to 8 feet; two-line system for lifts exceeding 8 feet.
  • Electrode Setting (PO Series): 5/32" gap, 5/16" above CL, 1/16" from nozzle.
  • CO2 Content (Flue Products): 8.0-9.0% (natural gas), 9.0-10.0% (LP gas).

Usage Features:

  • Direct Ignition: Gas models feature an automatic ignition device; no pilot light.
  • Convertibility: Easily switch between power oil and power gas, and adjust firing rates with a certified conversion kit.
  • Thermostat Control: Standard room thermostat connections for operation. Heat anticipator adjustment: 0.4 amps (oil), 0.9 amps (gas).
  • Fan Operation: FAN ON/OFF switch on the control box allows for automatic blower operation via thermostat or constant blower operation.
  • Safety Lockout: Equipped with safety features that will shut down the burner in case of issues like flame failure or centrifugal switch malfunction. Manual reset limits are included.
  • Air Quality Package (Accessory): Ventilaire III or IV packages can be installed to meet ventilation requirements by introducing outdoor air or exhausting moist/hot air from the attic.

Maintenance Features:

  • Air Filters: Should be inspected and cleaned monthly.
  • Combustion Air and Venting System: Inspect at the beginning and end of each heating season for deterioration, blockage, or damage. Clean as necessary.
  • Gas Burner Adjustment: Air shutter is factory pre-set but can be adjusted when converting firing rate. Proper adjustment ensures ample combustion air and quiet operation, preventing carbon monoxide production.
  • Oil Burner Electrode Setting: Electrodes are factory set but should be checked for proper positioning during installation to ensure good ignition.
  • Troubleshooting Guide: Comprehensive guide provided for both gas and oil furnaces, covering issues like burner motor not running, ignitor not heating up, main flame igniting but locking out, insufficient heat, and circulation blower not operating. Includes control module status indicators (flash codes) for gas furnaces and indicator light patterns for oil primary controls (Honeywell R7184 and Beckett 7505) to diagnose issues like lockout, recycle, and cad cell status.
  • Cad Cell Resistance Check (Oil Furnaces): Procedure to check cad cell resistance to diagnose flame sensing issues.
  • Important Safety Reminders: Always disconnect power before servicing. Only qualified personnel should service direct ignition systems. Never use a match or open flame to detect gas leaks. Ensure proper grounding and wiring. Do not use if submerged in water.