5
WARNING
appliance, read
Before install the
manual first.
the installation
The refrigerant
appliance, read
Before use the
the owner’s ma-
nual first.
the service ma-
appliance, read
Before repair the
nual first.
Qualification of workers
Safety operation of flammable refrigerant
Leak test is a must after installation.
A2L
Refrigeran t
Compared to common refrigerants, R32 is a
nonpolluting refrigeran t with no harm to the
ozonosphere. The influence upon the green-
house effect is also lower. R32 has got very
good thermodynamic features which lead to a
really high energy e fficiency. The units there
fore need a less filling.
Installation notes
Safety Group
A2L
Appliance filled with
flammable magas R32.
process or to clean,other than those recomm-
ended by the manufacturer.
Servicing shall be performed only as recomm-
ended by the manufacturer.
Should repair be necessary,contact your nearest
authorized Service Centre. Any repairs carried out
by unqualified personnel may be dangerous.
Compliance with national gas regulations shall
be observed.
Read specialist’s manual.
T
o realize the function of the air conditioner unit,
a special refrigeran t circulates in the system.
The used refrigerant is the fluoride R32, which
is specially cleaned.
The refrigerant is flammable
and inodorous. Furthermore, it can lead to ex-
plosion
under certain conditions. But the flam-
mability of the refrigerant is very low. It can be
ignited only by fire.
The air conditioner must be installed in a room
that is larger than the minimum room area. The
minimum room area is shown on the nameplate
or following table a.
It is not allowed to drill hole or burn the connec-
tion pipe.
Qualification of the working personnel for
maintenance, service and repair operations
should according to UL 60335-2 -40、CAN/C-
SA
-C22.2 No. 60335-2-40:22 Annex HH..
Every working procedure that affects safety
means shall only be carried out by compe-
tent persons according to Annex HH. Special
training additionalto usual refrigerating equip-
ment repair procedures is required when
equipment with FLAMMABLE REFRIGER-
ANTS is affected.
Ref rigera nt
Safety Group
The appliance shall be stored in a room without
continuously operating ignition sources.
(for example:open flames,an operating gas app-
liance or an operating electric heater.)
The appliance shall be stored in a well-
ventilated area where the room size
corresponds to the room area as specified for
operation.
The appliance shall be stored so as to prevent
mechanical damage from occurring.
Ducts connected to an appliance shall not con-
tain an ignition source.
Keep any required ventilation openings clear of
obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an
odour.
Do not use means to accelerate the defrosting
Appliance filled with flammable gas R32.
Appliance shall be installed, operated and
stored in a room with a floor area not less than
X m .
2
(Please refer to table "a" in section of " Safety
operation of flammable refrig erant " for
space X.)