NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
1
I
N S T A L L A T I O N
I
N S T R U C T I O N S
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
– Do not store or use gasoline or
other flammable vapors and liq-
uids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas sup-
plier from a neighbor’s phone.
Follow the gas supplier’s instruc-
tions.
• If you cannot reach your gas sup-
plier, call the fire department.
– Installation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided. Refer to combustion and
ventilation air section, page 3.
Due to high temperatures, the ap-
pliance should be located out of
traffic and away from furniture or
draperies.
Do not place clothing or other ma-
terials on or near this appliance.
PLEASE RETAIN THIS MANUAL FOR FUTURE
REFERENCE.
*Note: Manual control models are also design
certified for use as vented gas log sets.
Installation
And Operation
Instructions
Unvented Gas Log
Room Heaters
VFGL-18MSN-3 Series*
VFGL-18MSP-3 Series*
VFGL-24MSN-3 Series*
VFGL-24MSP-3 Series*
VFGL-28MSN-3 Series*
VFGL-28MSP-3 Series*
VFGL-18VSN-3 Series
VFGL-18VSP-3 Series
VFGL-24VSN-3 Series
VFGL-24VSP-3 Series
VFGL-28VSN-3 Series
VFGL-28VSP-3 Series

Other manuals for Nordyne VFGL-18MSP-3 Series

Questions and Answers

  • K
    kryanSep 8, 2025
    What to do if my Nordyne Gas Heater has a gas odor even when it's off?
    • J
      Julie WaltersSep 8, 2025
      If you smell gas from your Nordyne Gas Heater even when the control knob is in the 'OFF' position, it could be due to a gas leak. Locate and correct all leaks. Another possibility is a defective control valve, which would need to be replaced.
  • M
    Michael WalkerAug 23, 2025
    Why does my Nordyne VFGL-18MSP-3 smell?
    • J
      Jason MatthewsAug 23, 2025
      Your Nordyne heater might be producing unwanted odors because it's burning vapors from things like paint, hair spray, or glues. To fix this, ventilate the room and stop using odor-causing products while the heater is running. Another cause could be a gas leak, so locate and correct any leaks.
  • M
    Mallory SnyderAug 25, 2025
    What to do if Nordyne VFGL-18MSP-3 Heater has gas odor in OFF position?
    • P
      Peter GriffinAug 25, 2025
      If you smell gas from your Nordyne Heater even when the control knob is in the “OFF” position, there could be a gas leak. You'll need to locate and correct all leaks. Alternatively, the control valve might be defective, requiring replacement.
  • T
    Tara WardAug 26, 2025
    Why won't my Nordyne Heater burner light after ODS/pilot is lit?
    • M
      Michael WilliamsAug 27, 2025
      If the burner on your Nordyne heater won't light after the ODS/pilot is lit, the burner orifice might be clogged. Try cleaning the burner or replacing the burner orifice. Another possibility is that the burner orifice diameter is too small, requiring replacement. Also, the inlet gas pressure could be too low, so contact your local gas company.
  • A
    anthonyrobinsonAug 27, 2025
    What to do if Nordyne Heater has delayed ignition of burner?
    • J
      Jennifer HuberAug 27, 2025
      If your Nordyne Heater has a delayed ignition of the burner, it could be due to a couple of reasons. The manifold pressure might be too low, in which case you should contact your local gas company. Another cause could be a clogged burner orifice, so try cleaning the burner or replacing the burner orifice.
  • C
    Cassidy EricksonSep 22, 2025
    Why does my Nordyne Gas Heater have slight smoke or odor during initial operation?
    • M
      maria57Sep 22, 2025
      A slight smoke or odor during the initial operation of your Nordyne Gas Heater is likely due to vapors from paint or the curing process of the logs. This problem should stop after a few hours of operation; extra ventilation is recommended during this time. Avoid turning the control knob to the 'HI' position when the burner is cold; instead, turn it to 'LO' and let it warm up for a minute. Air in the gas line or a dirty burner orifice can also cause this issue. Operate the burner until the air is removed from the line and have the gas line checked, or clean the burner or replace the burner orifice.
  • A
    andrewmeltonSep 16, 2025
    Why is there no spark at ODS/pilot when pressing the igniter button on my Nordyne Gas Heater?
    • B
      Bruce JonesSep 16, 2025
      If there's no spark at the ODS/pilot when you press the igniter button on your Nordyne Gas Heater, the igniter electrode might be positioned wrong or broken, requiring replacement. Ensure the igniter electrode is connected to the igniter cable. Also, check if the igniter cable is pinched or wet; free it from any obstructions and keep it dry. A loose piezo igniter nut should be tightened. If the igniter cable is broken or the piezo igniter is bad, replace them accordingly.
  • M
    Megan VasquezSep 18, 2025
    What to do if there is spark at ODS/pilot, but no ignition in Nordyne Gas Heater?
    • B
      Brian PattersonSep 18, 2025
      If there's a spark at the ODS/pilot but no ignition in your Nordyne Gas Heater, first check if the gas supply is turned on and the manual shut-off valve is open. Ensure the control knob is in the 'PILOT' position and pressed in. If there's air in the gas lines, continue holding down the control knob and repeat the igniting operation until the air is removed. A clogged ODS/pilot might also be the cause, requiring replacement or service. If the gas regulator setting is incorrect, replace the gas regulator.
  • M
    Michelle CampbellSep 7, 2025
    Why does my Nordyne Gas Heater shut off in use?
    • M
      Monica HernandezSep 7, 2025
      Your Nordyne Gas Heater might be shutting off during use because there isn't enough fresh air available. Try opening a window or door for ventilation. Alternatively, it could be due to low line pressure, in which case you should contact your local gas company. A partially clogged ODS/pilot can also cause this issue; try cleaning the ODS/pilot.
  • T
    Thomas MitchellSep 4, 2025
    How to fix no spark at ODS/pilot on Nordyne VFGL-18MSP-3?
    • E
      Elizabeth McdonaldSep 4, 2025
      If there is no spark at the ODS/pilot when you press the igniter button on your Nordyne Heater, the igniter electrode might be positioned wrong or broken, in which case you should replace the igniter. Check if the igniter electrode is connected to the igniter cable; if not, reconnect it. The igniter cable could also be pinched or wet, so free it if pinched and keep it dry. Ensure the piezo igniter nut is tight. If the igniter cable is broken, replace it. If the piezo igniter is bad, replace it.