4.
Before Installation
Checkup
Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
DANGER
Do Not Use Equipment for Purposes Other Than Those Specified
Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
Check that the rating plate indicates the
correct type of gas.
Check that the gas supply line is sized for
199,900 Btuh for this unit.
Check the Power
The power supply required is 120VAC, at 60Hz.
Using the incorrect voltage may result in fire or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
Precautions on Vent Pipe Replacement
Only use vent materials that are specified in this Installation Manual for use on this appliance. Refer
to the "Vent Pipe Installation" section for details. If PVC, CPVC, or Category IV listed pipe is already
installed, check for punctures, cracks, or blockages and consult with the vent pipe manufacturer
before reusing.
Improper venting may result in fires, property damage or exposure to Carbon Monoxide.
Snow Precaution
If this product will be installed in an area where snow is known to accumulate, protect the vent
termination from blockage by snow drifts or damage from snow falling off of roofs.
199,900
186 000186,000
3.6
3.35 3.35
3.6
192,700
179 300179,300
199,900 BTU
11,000 BTU
222
4.0
0.75 3.35
10.5
840
10.3a-2007
15
150
4.3a-2007
4
.NCC199-DV

Other manuals for Noritz N-0841MC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Noritz N-0841MC Series and is the answer not in the manual?

Noritz N-0841MC Series Specifications

General IconGeneral
BrandNoritz
ModelN-0841MC Series
CategoryWater Heater
LanguageEnglish

Related product manuals