1. Features
1. Quick Connect Multi System (For N-0751M series, N-0931M series, N-0841MC series, and N-1321M-ASME only)
Allows the simple installation of up to 2 units linked together using a Quick Connect Cord
CCP Valve
System Controller
2. Secondary Recirculation Pump in a Multi-System (For N-0931M series, N-0841MC series, and N-1321M-ASME only)
T wo recirculation pumps can be connected to the multi-system controller to provide a rotational pump system.
The multi-system controller will rotate the run time of each pump to increase pump life and also provide a backup
should one pump fail.
3. Multi-System Rotation Timing (For N-0931M series, N-0841MC series, and N-1321M-ASME only)
(1) In a multi-system installation, the system controller rotates the primary unit every 8 hours of accumulated
combustion time.
of up to 16 hours).
(3) Rotation is made every 24 hours, regardless of the burn, to ensure even wear.
4. Maximum Remote Controller Length (Only one remote controller can be connected.)
Remote controller (1 unit): Cord can be extended up to 300' with 18AWG wire.
* Note: In a Quick Connect Multi-System, only one remote controller will be installed.
(For N-0751M series, N-0931M series, N-0841MC series, and N-1321M-ASME only)
5. Temperature Lockout Function
The remote controller can be set to restrict the maximum allowable temperature setting for added safety.
See page 55-56 for details.
6. Elevation Adjustment
of the unit. No additional equipment or adjustments are necessary. See the "Installation Manual" for details.
Not required