EasyManua.ls Logo

Norpe NORCON - NRC-100 Control Device; NRC-100 Display Messages

Norpe NORCON
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The cabinet is not designed to cool down products but to maintain them at the
temperature at which they are placed in the cabinet. Food products warmer than
the specified temperature should not be placed in the cabinet.
NOTE
4.3. Setting operating thermostat
The operating thermostat for the cabinet is located in the terminal box inside the machinery
compartments. The lid to the machinery compartment is fixed with a spring. The thermostat is
preset to the correct temperature at the factory.
4.4. Control devices
There are two types of control devices the cabinets can use. The table below illustrates which
control device can be used.
Dixell XR40CXNRC-100
XXNorCon
XXDeli
4.5. NRC-100 control device
The type of the control device depends on the cabinet.NOTE
NRC-100 is a cabinet controller that automates cabinet defrosting by means of a thermostat and
temperature sensor.
4.5.1. Display messages
In normal status, the display shows cabinet temperature.
Defrosting signals
Waiting for other cabinets
when synchronising defrost.
Pull down. Cooling until
expected temperature is
reached.
Defrosting under way.
Probe failure alarm signals
Cabinet temperature probe
failure. Contact service.
Evaporator probe failure.
Contact service.
Thermostat probe failure. Contact
service.
7Version 2/2013
ENGLISH
PI

Table of Contents

Related product manuals