Proven Performance
MODEL 27500 PTOG
ITEM # 165937
Power T
ake-Off Generator
M165937D
OWNER’S MANUAL
Any Questions, Comments, or Problems?
Call Customer Service at 1-800-270-0810
Hours: Monday - Friday 7:30 AM to 5:30 PM
Saturday 7:30 to 11:30 AM CST
THANK YOU

Questions and Answers

  • M
    mcculloughjamesJul 30, 2025
    What to do if the circuit breaker trips on my North Star Inverter?
    • B
      Brandy HaneyJul 30, 2025
      If the circuit breaker trips, it might be due to several reasons. First, the engine speed could be too slow, in which case you should increase the tractor RPMs. Second, the generator might be overloaded, so reduce the load. See Load Application section of this manual. Third, a defective load might be connected; disconnect it. Fourth, the receptacle could be defective; replace it.
  • D
    David AlexanderAug 9, 2025
    How to fix voltage that is too low on a North Star Inverter?
    • L
      Lisa WallaceAug 9, 2025
      If the voltage is too low, try increasing the tractor RPMs. Alternatively, reduce the load. See Load Application section of this manual.
  • E
    Eileen WilliamsAug 18, 2025
    Why is there excessive gear box noise in my North Star Inverter?
    • A
      Aaron CampbellAug 18, 2025
      Excessive gearbox noise can be caused by several factors. It could be due to no or low gear oil, in which case you should fill the gear box to the oil level sight. Also, the PTO driveline may be operating at an angle greater than 15°; reposition the tractor or generator so the angle is reduced to less than 15° both vertically and horizontally. Finally, an unsynchronized PTO driveline can cause noise; disassemble the PTO driveline and reassemble with CV joints synchronized.

Summary

ANSI Safety Definitions

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in a death or serious injury.

CAUTION

Indicates a potentially hazardous situation, which if not avoided, may result in minor or moderate injury.

Machine Component Identification

Generator Features

Introduction

Rules for Safe Operations

Installation

Load Application

Starting Electric Motors

Extension Cords

Pre-Start Up Preparations

Grounding

All units must be grounded by driving a copper pipe or rod into moist earth and connecting to the generator.

Operating Speed

Generator must run at correct speed for proper voltage and frequency. Check output voltage with a load.

Generator Care

Exercising The Generator

Operate generator every four weeks for 15 minutes with a load to dry windings and ensure readiness.

Generator Maintenance

Generator head is maintenance-free. Major service by qualified technicians using approved parts.

North Star 27500 Specifications