MODEL 2900 BDG, ITEM # 165915
Belt Driven Generator
M165915A
OWNER’S MANUAL
00035
2900 BDG
Questions or comments? Call 1-800-270-0810

Questions and Answers

  • K
    Krista KingJul 30, 2025
    What to do if my North Star 2900 Inverter has no output voltage?
    • R
      Richard SweeneyJul 30, 2025
      If your North Star Inverter shows no output voltage, it could be due to several reasons. First, a defective load connected to the generator might be the cause, so disconnect the load. Another possibility is a defective receptacle, which would require replacement. Lastly, the generator might be overloaded, in which case you should reduce the load.
  • V
    vroseAug 5, 2025
    Why does the circuit breaker trip on my North Star 2900?
    • M
      Maria HardinAug 5, 2025
      The circuit breaker on your North Star Inverter might be tripping because the engine speed is too slow, in which case you should disconnect the load. Alternatively, the generator could be overloaded, so you should reduce the load.
  • S
    sarahsotoAug 11, 2025
    What to do if my North Star 2900 Inverter is overloaded?
    • C
      Carrie MackAug 11, 2025
      If your North Star Inverter is overloaded, you should reduce the load. Additionally, try cleaning or replacing the air filter.
  • D
    Darlene BlakeAug 17, 2025
    What to do if my North Star Inverter is overheating?
    • M
      Michael WilsonAug 17, 2025
      If your North Star Inverter is overheating, it may be due to insufficient ventilation. Ensure there is at least 3 feet of clearance on all sides of the generator.
  • J
    Jacob GonzalezAug 23, 2025
    Why is the voltage too high on my North Star Inverter?
    • J
      Jose BarnesAug 23, 2025
      If the voltage on your North Star Inverter is too high, it may be because the engine speed is too high, in which case you should bring generator to a qualified technician for adjustment. Another possible cause is that the generator is overloaded, so reduce the load.

Summary

Introduction, Safety Definitions, and Safe Operations

Grounding Screw Warning

Emphasizes completing the grounding path to prevent electrical shock.

Wet Conditions Operation

Warns against operating in water, barefoot, or in rain/snow to prevent shock.

Adequate Ventilation Requirement

Stresses the need for ventilation to prevent carbon monoxide buildup.

Installation and Power Transmission

Guarding and Exhaust Safety

Warns about dangers of pinch points without guards and carbon monoxide.

Load Application and Motor Starting

Starting Electric Motors

Explains the higher current requirements for starting electric motors.

Generator Load Requirements and Operation

Grounding Procedure

Details the steps for properly grounding the generator to moist earth.

Operating Speed and Voltage

Explains the importance of correct speed for voltage and frequency output.

Generator Care and Stand-by Operation

Stand-by Operation Warning

Mandates licensed electrician installation and proper transfer switch for utility failure use.

Troubleshooting Generator Issues

Voltage Too Low

Addresses causes like slow engine speed or overload, and remedies.

Circuit Breaker Trips

Covers defective loads, receptacles, or generator overload as causes.

Voltage Too High

Identifies high engine speed as the primary cause and suggests adjustment.

Generator Overheating

Attributes overheating to overload or insufficient ventilation, offering solutions.

North Star 2900 Specifications

General IconGeneral
AC Output Power2900W
WaveformPure Sine Wave
Frequency60 Hz
ProtectionsOverload, Short Circuit
CoolingFan Cooling