Operation
16
2) Press the Engine Start/Stop button to start the
engine (Engine Start/Stop button will blink green
illumination while engine start and turn solid
green once engine has successfully started).
NOTICE:
The engine will repeat the start
sequence three times if the engine
fails to start. To terminate startup,
toggle the engine switch to the
"OFF" position.
When not in use, keep the engine
switch at the "OFF" position to
avoid the loss of battery power.
Shutdown of the Engine (Recoil Models
Only):
114593 (804313) and 114594 (804314):
1. Toggle the engine switch to
the "OFF" position.
Shutdown of the Engine (Electric Start
Model Only):
114656 (804315):
1. Press and release the
Engine Start/Stop button
(Engine Start/Stop will blink
red while engine is stopping
and turn solid red once
engine has successfully
shutdown).
2. Toggle the engine switch
to "OFF" position.
NOTE:
In case of emergency, the engine
switch can be directly toggled
to the "OFF" position.
When not in use, keep the engine
switch at the "OFF" position to
avoid the loss of battery power.