Dispenser DP 30
Instructions for use
EN

Other manuals for Nouvag Dispenser DP 30

Questions and Answers

  • H
    hsmithAug 4, 2025
    Why Nouvag Water Pump doesn't work but the indicator light is on?
    • J
      johnsonjoyAug 4, 2025
      If your Nouvag Water Pump's indicator light is on, but the pump isn't working, consider these potential causes: * The control switch may be set too low or to “Off.” Try raising the pump performance by turning the control switch up. * The tubing set might be incorrectly inserted. Ensure it's correctly inserted, paying attention to the direction. * The pedal may not have been pressed. Press the pedal. * The roller clamp may be closed. Open the roller clamp all the way.
  • D
    Daniel RamirezAug 11, 2025
    What to do if my Nouvag Medical Equipment device is not functional and the indicator light is off?
    • A
      ashleyjacksonAug 12, 2025
      If your Nouvag Medical Equipment device isn't working and the indicator light is off, here's what you can check: * Ensure the control unit is switched on by setting the power switch "I/O" to "I". * Verify the power connection to the mains power supply. * Confirm the operating voltage is correct. * Inspect and replace the fuse if it's faulty.
  • M
    Michelle SmithAug 19, 2025
    Why is the pump not working on my Nouvag Medical Equipment, even though the indicator light is on?
    • K
      Kent Herrera IIAug 19, 2025
      If the pump on your Nouvag Medical Equipment isn't working but the indicator light is on, consider the following: 1. Check if the control switch is set too low or to the “Off” position. If so, raise the pump performance by turning the control switch up. 2. Verify that the tubing set is correctly inserted, paying attention to the direction. 3. Ensure correct operation by checking the operating instructions. 4. Confirm that the pedal is pressed and the roller clamp is fully open.
  • M
    marcus39Aug 26, 2025
    How to fix a Nouvag Medical Equipment pedal that isn't working, even though the indicator light is on?
    • M
      Michael PopeAug 26, 2025
      If the pedal of your Nouvag Medical Equipment isn't working while the indicator light is on, it might be due to the pedal not being connected. Ensure the pedal is connected to the socket on the rear of the device. Also, make sure that you are operating the device correctly by checking the operating instructions.

Summary

Foreword

Explanation of symbols

Post market surveillance

Product description

Intended use and operation

Details the device's purpose and application fields.

Target group

Specifies the intended user group for the device.

Contraindications

Lists conditions where the device should not be used.

Technical data

Provides key technical specifications of the Dispenser DP 30.

Ambient conditions

Specifies operating and storage environmental requirements.

Warranty coverage

Outlines the terms and conditions of the product warranty.

Safety information

EMC Manufacturers Declaration of Conformity

Declares compliance with electromagnetic compatibility standards.

Integrated peristaltic pump

Describes the function and limitations of the peristaltic pump.

Possible risks and side effects

Details potential hazards and adverse outcomes from device use.

Modification and misuse

Warns against unauthorized changes and improper use of the device.

Essential requirements

Lists crucial prerequisites for safe and proper device operation.

During use

Provides safety guidelines to follow while operating the device.

Device overview

Front view

Illustrates and labels components visible from the front of the device.

Rear view

Illustrates and labels components visible from the rear of the device.

Startup

Connection to the power supply

Instructions for connecting the device to the electrical power source.

Potential equalization connection

Details the procedure for connecting the potential equalization.

Device preparation

Steps to prepare the device and accessories before operation.

Device setup

Instructions for correctly positioning and setting up the device.

Operation

Switching the device on and off

How to turn the device power on and off.

Regulation of the infiltration process

Explains how to control the infiltration flow rate using controls and pedals.

Peristaltic pump

Describes the operation of the peristaltic pump mechanism.

Functional check

Procedure to verify the device is working correctly before use.

Cleaning and disinfection

Control unit and pedal

Instructions for cleaning the main unit and pedal.

Tube set REF 6022

Guidelines for handling and using the disposable tubing sets.

Maintenance

Replacing the control unit fuse

Step-by-step guide to replace a blown fuse.

Safety inspections

Information on mandatory safety checks and their frequency.

Information on disposal

Guidance on how to properly dispose of the device and accessories.

Malfunctions and troubleshooting

Spare parts list with order numbers

Service center

Electromagnetic compatibility (EMC)

Guidance and manufacturers declaration - electromagnetic emissions

Manufacturer's declaration regarding electromagnetic emission compliance.

Guidance and manufacturers declaration - electromagnetic immunity

Manufacturer's declaration regarding electromagnetic immunity.

Nouvag Dispenser DP 30 Specifications