BEFORE OPERATION
Check Oil Engine will not operate with incorrect oil level (P. 16-17).
Check Fuel Level and move fuel cap vent to ‘ON’ position Starting with
a full tank will help to eliminate or reduce operating interruptions for
refueling.
Check Eco-Mode switch* Switched to off position
Check Loads - The generator may be hard to start if a load is connected.
It is recommended that all loads are disconnected from generator during
start.
Fuel Type Ensure fuel type selector switch is set to correct fuel. If
switching fuel type, see P. 12-14 of this guide for fuel changing
procedure.
Note: JP-8/F-24/Jet-A/Kerosene-1 are primary fuels for this generator.
Generator will run optimally on these kerosene-based fuels.
Check Air Filter Check air filter per the maintenance schedule (P. 16).
Helpful hints:
Oil level: Engine will not operate if oil level is too low OR too high. Fill oil
to correct level (see P. 16-17). If many attempts to start are made with
inadequate or too much oil, spark plug may become fouled. Spark plug
may need to be cleaned or replaced with a new spark plug before engine
will start.
Fuel type change: Generators are shipped ready to operate on JP-8 or F-
24. Switching fuel type, from JP-8 to gasoline for example, requires
careful attention. Please refer to P. 12-14 for instructions on switching
fuels.
*applies to generators equipped with Eco-mode