Novo Clear 485
Automatic Water Filters
Multi-Media
Neutralizing
Carbon
Installation and Operation Manual
REVISION # 1
REVISION DATE NOVEMBER 12, 2012
1. Read all instructions carefully before operation.
2. Avoid pinched o-rings during installation by applying (provided with install kit) NSF certified
lubricant to all seals.
3. This system is not intended for treating water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Proud member of Canadian Institute of Plumb-
ing & Heating.
Canadian Head Office
655 Park St.
Regina, SK S4N 5N1
Eastern Sales & Distribution
20 Steckle Place, Unit 21
Kitchener ON N2E 2C3
Proud member of Canadian Water Quality Asso-
ciation.

Questions and Answers

  • E
    edwardfarmerJul 31, 2025
    How to fix a NOVO Clear 485 Water Filtration Systems that won't start regeneration cycle?
    • B
      Brandi DyerJul 31, 2025
      If your NOVO Water Filtration System isn't starting its regeneration cycle, it could be due to a few reasons. First, check the electrical service, fuse, and other power-related components to ensure the unit is receiving power. A defective circuit board could also be the cause, requiring replacement of the faulty parts. Lastly, a power failure might have occurred; if so, simply reset the time of day on the unit.
  • M
    mcclurepaigeAug 10, 2025
    What to do if NOVO Water Filtration System has continuous flow to drain?
    • N
      nnewtonAug 10, 2025
      Continuous flow to the drain in your NOVO Water Filtration System can be caused by several issues. Begin by verifying that the valve settings are correct. Foreign material lodged in the control valve could also be responsible, so clean the control thoroughly. Finally, an internal leak might be the cause; in this case, replace the seals, spacers, and piston assembly.
  • S
    Shirley MeadowsAug 15, 2025
    How to increase water pressure in NOVO Clear 485 Water Filtration Systems?
    • A
      Andrea JacobsAug 15, 2025
      Low water pressure in your NOVO Water Filtration System can stem from a few issues. Iron or scale buildup in the line feeding the unit might be the cause, so cleaning the pipes is recommended. Alternatively, iron buildup inside the valve or tank could be the problem; clean the control and add resin cleaner to clean the bed, and consider increasing regeneration frequency. Lastly, the inlet of the control might be plugged due to foreign material; remove the piston and clean the control valve to resolve this.
  • N
    Nicole MendezAug 19, 2025
    Why is there filter media in the drain line of my NOVO Water Filtration System?
    • M
      Matthew BooneAug 19, 2025
      Filter media appearing in the drain line of your NOVO Water Filtration System can be attributed to a couple of reasons. First, check the well system for proper air eliminator control, as air in the water system can cause this issue. Additionally, an incorrect drain line flow control (DLFC) button might be the culprit, so verify that it's set for the proper flow rate.
  • R
    robertsdouglasAug 26, 2025
    What to do if valve continuously cycles on NOVO Clear 485 Water Filtration Systems?
    • S
      Shannon GonzalezAug 26, 2025
      If the valve of your NOVO Water Filtration System is continuously cycling, the defective position sensor PCB is the cause. Replace faulty parts.
  • C
    Christopher SalazarNov 3, 2025
    Why does my NOVO Water Filtration System bleed taste and odor?
    • J
      James GarciaNov 4, 2025
      If your NOVO Water Filtration System is bleeding taste, odor, or sediment, several factors could be at play. First, ensure the bypass valve is closed. Check that the unit has continuous electrical service by verifying the fuse, plug, and switch. The media bed might be defective or stripped, requiring replacement. A change in water quality may also be the culprit, so have a sample analyzed. The filter capacity might be insufficient, suggesting a replacement with a larger unit or the addition of another filter. Ensure the filter is backwashing adequately by checking for clogs in the control or restrictions in the drain line, and confirm that the water pressure and pump capacity are sufficient. Finally, inspect for leaks between the valve and central tube, checking for cracks or damage to the...

Summary

System Start-Up

Key Pad Configuration

Explains the function of the SETTINGS, MANUAL REGEN, UP, and DOWN buttons.

Manual Regeneration (Step; Cycle Valve)

Describes how to initiate delayed or immediate regeneration cycles.

Backwash Frequency

Automatic Raw Water Bypass During Regeneration

Maintenance

Loading the Media Pak

Main Repair Parts

Filter Exploded View

Control Valve Exploded View

Control Valve Parts List

Power Head Exploded View

Power Head Parts List

Trouble Shooting

Warranty

NOVO Clear 485 Specifications

General IconGeneral
BrandNOVO
ModelClear 485
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals