OPERATION MANUAL
STALLION 12 SC CARPET EXTRACTOR
SAVE THESE INSTRUCTIONS
ALL REPAIR SERVICE MUST BE PERFORMED
BY AN NSS AUTHORIZED DISTRIBUTOR /
ERVICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.
ICE STATION USING ONLY NSS ORIGINAL EQUIPMENT PARTS.
S
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS
Read all instructions before using or servicing machine.Read all instructions before using or servicing machine.
WARNING: Shock or electrocution hazard. WARNING: Shock or electrocution hazard.
ALWAYS unplug machine before
performing any maintenance or service.
ALWAYS unplug machine before
performing any maintenance or service.
WARNING: Shock or electrocution hazard. WARNING: Shock or electrocution hazard.
NEVER connect this machine to an
electrical outlet that is not properly
grounded. See grounding instructions.
NEVER connect this machine to an
electrical outlet that is not properly
grounded. See grounding instructions.
WARNING: Fire or explosion hazard.
NEVER use to pick up flammable or
combustible liquids, or any thing that is
burning or smoking, such as cigarettes,
matches or hot ashes.
WARNING: Fire or explosion hazard.
NEVER use to pick up flammable or
combustible liquids, or any thing that is
burning or smoking, such as cigarettes,
matches or hot ashes.
NEVER operate this machine in an
explosive atmosphere (grain dust,
flammable liquids or fumes, etc…)
NEVER operate this machine in an
explosive atmosphere (grain dust,
flammable liquids or fumes, etc…)
WARNING: To reduce the risk of fire, electric shock, or injury:WARNING: To reduce the risk of fire, electric shock, or injury:
INTENDED USE INTENDED USE
The Stallion 12 SC Carpet Extractor is intended for
commercial use, cleaning and extracting floors, furniture,
draperies and automobile interiors in an indoor
environment. This machine is intended for Wet pickup
only. NSS does not recommend using these machines
for any other purpose.
The Stallion 12 SC Carpet Extractor is intended for
commercial use, cleaning and extracting floors, furniture,
draperies and automobile interiors in an indoor
environment. This machine is intended for Wet pickup
only. NSS does not recommend using these machines
for any other purpose.
When Using An Electrical Appliance, Basic
Precautions Should Always Be Followed,
Including The Following:
When Using An Electrical Appliance, Basic
Precautions Should Always Be Followed,
Including The Following:
ALWAYS read and understand all instructions before
operating or servicing machine.
ALWAYS read and understand all instructions before
operating or servicing machine.
ALWAYS use this machine ONLY as described in this
manual.
ALWAYS use this machine ONLY as described in this
manual.
NEVER attempt to operate this machine unless you
have been trained in its operation.
NEVER attempt to operate this machine unless you
have been trained in its operation.
NEVER allow an untrained person to operate this
machine.
NEVER allow an untrained person to operate this
machine.
NEVER leave the machine plugged in to the electrical
outlet when not in use.
NEVER leave the machine plugged in to the electrical
outlet when not in use.
NEVER unplug the machine from an electrical outlet
until after the machine is turned off.
NEVER unplug the machine from an electrical outlet
until after the machine is turned off.
If appliance is not working as it should, has been
dropped, damaged, left outdoors, or dropped into
water, return it to a service center.
If appliance is not working as it should, has been
dropped, damaged, left outdoors, or dropped into
water, return it to a service center.
NEVER operate this machine in standing water. NEVER operate this machine in standing water.
NEVER disconnect or modify any switches or safety
devices.
NEVER disconnect or modify any switches or safety
devices.
NEVER operate this machine if the cord and / or plug
has been damaged, broken, cut, abraded or taped.
NEVER operate this machine if the cord and / or plug
has been damaged, broken, cut, abraded or taped.
ALWAYS replace the entire cord when the cord or
plug is damaged in any way.
ALWAYS replace the entire cord when the cord or
plug is damaged in any way.
NEVER handle the machine, cord, or plug with wet
hands.
NEVER handle the machine, cord, or plug with wet
hands.
NEVER drop or insert any object into any machine
opening.
NEVER drop or insert any object into any machine
opening.
NEVER operate this machine with any air opening
blocked. Keep all air openings free of dust, lint, hair,
etc.
NEVER operate this machine with any air opening
blocked. Keep all air openings free of dust, lint, hair,
etc.
NEVER pull or carry the machine by its electrical
supply cord, use the cord as a handle, close a door on
the cord, pull the cord around sharp edges or corners,
expose to heated surfaces, run machine over cord, or
set heavy or sharp objects on the cord.
NEVER pull or carry the machine by its electrical
supply cord, use the cord as a handle, close a door on
the cord, pull the cord around sharp edges or corners,
expose to heated surfaces, run machine over cord, or
set heavy or sharp objects on the cord.
NEVER unplug by pulling on the cord. To unplug the
cord from the outlet, grasp the plug, not the cord.
NEVER unplug by pulling on the cord. To unplug the
cord from the outlet, grasp the plug, not the cord.
NEVER allow this machine to be used as a toy. Close
attention is necessary when used by or near children.
NEVER allow this machine to be used as a toy. Close
attention is necessary when used by or near children.
ALWAYS keep face, fingers, hair or any other body
part or loose clothing away from any machine opening
or moving part.
ALWAYS keep face, fingers, hair or any other body
part or loose clothing away from any machine opening
or moving part.
ALWAYS use extreme care when cleaning on stairs
or when machine is placed on stairs.
ALWAYS use extreme care when cleaning on stairs
or when machine is placed on stairs.
NEVER operate the machine without the filters in
place.
NEVER operate the machine without the filters in
place.
ALWAYS place this machine on a firm flat surface. ALWAYS place this machine on a firm flat surface.
NEVER use any attachments other than the
manufacturers recommended attachments.
NEVER use any attachments other than the
manufacturers recommended attachments.
NEVER spray this machine with water or any liquids. NEVER spray this machine with water or any liquids.
NEVER operate this machine outdoors. NEVER operate this machine outdoors.
NEVER expose the machine to rain, snow, or extreme
temperatures.
NEVER expose the machine to rain, snow, or extreme
temperatures.
NEVER use this machine for dry vacuuming. NEVER use this machine for dry vacuuming.
ALWAYS store this machine indoors in a dry, cool
area.
ALWAYS store this machine indoors in a dry, cool
area.
Stallion 12 SC O
p
eration Manual Ori
g
. 05-07 9094813

Questions and Answers

  • J
    James WardAug 13, 2025
    Why NSS STALLION 12 SC has no electrical power?
    • M
      Michael BakerAug 13, 2025
      If your NSS Floor Machine has no electrical power, it might be due to an overloaded circuit breaker. Try resetting the circuit breaker and unplugging other electrical items on the same circuit. Another possible cause is a defective power cord, which would need to be replaced.
  • L
    Lynn JordanAug 17, 2025
    What to do if NSS STALLION 12 SC has poor water pickup?
    • B
      bcarrAug 17, 2025
      If you're experiencing poor water pickup with your NSS Floor Machine, several factors could be responsible. Check the vacuum lid to ensure it's sealing properly; replace or tighten it if necessary. Also, inspect the vacuum hose and connections for any looseness and tighten them. Other potential issues include accumulated dirt on the lid screen (clean it), a worn vacuum lid gasket (replace it), lint and dirt buildup on the suction head/brush chamber (clean it), a defective vacuum hose (replace it), or a loose connection to the vacuum motor (tighten it).
  • B
    Beth FlynnAug 25, 2025
    What to do if NSS STALLION 12 SC Floor Machine pump runs but has little or no output?
    • D
      dguzmanAug 25, 2025
      If the pump on your NSS Floor Machine runs but produces little to no output, it could be due to several reasons. Internal pump parts may be worn, requiring you to rebuild the pump head or replace the pump. The pump might be air locked, so bleed the air lock from the system. A solenoid valve that won't open (replace the solenoid valve) or a plugged solution tank filter (clear or replace) could also be the cause.
  • N
    Natalie HinesAug 28, 2025
    What to do if NSS STALLION 12 SC Floor Machine pump motor will not run?
    • W
      watersrobertAug 28, 2025
      If the pump motor on your NSS Floor Machine won't run, it could be due to a few reasons. The motor might be shorted out, requiring a replacement. A faulty pressure switch could also be the culprit, and it would need to be replaced. Other potential issues include a faulty pump switch or wiring (repair or replace), a damaged power cord (replace it), an inadequate extension cord (remove it), or low voltage (test the wall outlet).
  • R
    Robert RaySep 1, 2025
    Why carpet spray is off but solution still drips from NSS STALLION 12 SC Floor Machine?
    • S
      Sean SmithSep 1, 2025
      If the carpet spray is off but solution continues to drip from your NSS Floor Machine, the cause might be debris in the solenoid. In this case, you should clean or replace it.
  • C
    christina67Sep 5, 2025
    Why motor runs but brush won’t spin on NSS STALLION 12 SC Floor Machine?
    • M
      Mariah ParkerSep 5, 2025
      If the motor runs but the brush won’t spin on your NSS Floor Machine, the issue might be a loose belt. Try tightening the belt.
  • R
    Roberto RivasSep 9, 2025
    How to fix floating brush that won’t move up and down on NSS STALLION 12 SC?
    • B
      Brandon HarrisSep 9, 2025
      If the floating brush on your NSS Floor Machine won’t move up and down, it could be due to debris inside the slide block guide. Disassemble and clear the obstruction to resolve this issue.
  • O
    Olivia HarrisNov 19, 2025
    How to fix uneven spray pattern from spray tips on NSS STALLION 12 SC Floor Machine?
    • M
      Matthew FieldsNov 19, 2025
      An uneven spray pattern or lack of solution from the spray tips on your NSS Floor Machine can stem from several issues. Start by checking if the spray nozzle tips are plugged and, if so, disassemble and clean them. Ensure the solution tank isn't empty and refill if needed. Other potential causes include a failed pump (repair or replace), a defective pump seal (replace the pump), debris in the check valve (clear the obstruction), a nozzle gasket obstruction (replace the gasket), incorrect spray nozzles (install correct ones), a clogged solenoid valve (bleed air lock from system), a worn pump bearing (repair or replace), a punctured pump diaphragm (replace diaphragm), accumulated dirt on the solution intake screen (clean or replace), accumulation of debris inside pump and plumbing (disassemb...

Summary

Important Safety Instructions

General Safety Warnings

Key warnings for shock, fire, and explosion hazards.

Intended Use

Defines the commercial, indoor use of the carpet extractor for wet pickup only.

Electrical Appliance Precautions

Basic safety guidelines for operating electrical appliances.

Grounding of Electrical Equipment

Grounding Instructions

Detailed steps for proper grounding of the machine to prevent electric shock.

Noise and Vibration

Noise Levels

Specifies the sound pressure level at the operator's position.

Machine Inspection

Machine Components

Solution Tank

Describes the lower part of the machine body holding cleaning solution.

Recovery Pails

Identifies the upper part of the machine body for collecting dirty water.

Control Panel

Details the components on the handle that control machine functions.

Cleaning Solution Flow Rate Valve

Explains the valve for adjusting cleaning chemical usage.

Brush Head Assembly

Describes the floating assembly that adapts to carpet pile heights.

Vacuum Shoe

Located at the front, this part pulls liquid from the carpet.

Accessory Hose Option

Information on connecting an optional hose assembly for different cleaning tasks.

Preparing the Machine

Preparing Solution and Recovery Tanks

Instructions for filling and preparing the machine's tanks before operation.

Connecting the Power Cord

Steps for securely connecting the machine's twist-lock power cord.

Brush Motor Circuit Breaker

Explains the function and reset procedure for the brush motor's circuit breaker.

Machine Operation

Normal Cleaning

Step-by-step guide for standard carpet extraction procedures.

Special Cleaning Procedures

Methods for performing non-standard cleaning tasks like double scrubbing.

Option - Accessory Cleaning

Preparing Accessories

Guidance on selecting and connecting cleaning tools and hoses.

Cleaning Upholstery, Stairs, or Confined Areas

Instructions for using accessories on non-floor surfaces.

Priming the Solution Pump

Procedure to remove air from the solution pump and lines.

Machine Maintenance

Daily Maintenance

Routine tasks to perform at the end of each day's operation.

Weekly Maintenance (25 Hours)

Recommended maintenance tasks to be performed weekly or after 25 hours.

Mandatory Periodic Maintenance

Essential maintenance procedures required for machine longevity.

Common Stains and Cleaning Treatments

Treatment Methods

General methods for removing various types of stains from carpets.

Troubleshooting

NSS STALLION 12 SC Specifications

General IconGeneral
Pad Speed175 rpm
Brush Speed175 rpm
Cleaning Path12 inches
Pad Size12 inches
Working Width12 inches
Cord Length50 feet